machine-extracted · confidence unavailable · Check page ↗ATC indoor air quality measurements conducted June 11, 2002 for PS 89M per BOE request.
NYC-WTC_000313849–000313852OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan June 12, 2002 Indoor Air Quality Assessment Page 3 P. S. 89M_______________________________ ATC Project No. 15-19125-0297 Real-Time Environmental Measurements
ATC collected seventy-nine (80) sets of real-time environmental measurements consisting of seventy (70) from inside the school building and ten (10) from outdoors. All five floors of the school building were surveyed. These results are described below.
Field data sheets are found in Attachment 1. Readings began at 8:00 A.M. and concluded at approximately 10:01 A.M.
Temperature
Indoor dry bulb temperature measurements ranged from 70.2 °F to 78.1 °F. Twenty-nine (29) of the indoor measurements for temperature were below the range of 73 to 79°F (at 50 percent relative humidity) as recommended by the ASHRAF Standard 55-1992 during the summer season. The outdoor temperature measurements ranged from 73.9 °F to 74.1 °F.
Relative Humidity
The relative humidity indoors ranged from 44.3 to 55.6 percent. All of the indoor measurements for relative humidity were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity measurements ranged from 59.9 to 60.1 percent.
Carbon Dioxide Concentration
Carbon dioxide concentrations indoors ranged from 515 ppm to 1281 ppm. All of the indoor measurements for CO2 were within the ASHRAF Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The maximum outdoor (background) CO2 concentration was 600 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1300 ppm (background level + 700 ppm). Carbon dioxide measurements are used as an indicator of available outside makeup air. The primary source of CO2 indoors is occupant respiration. The school building was occupied during ATC’s assessment.
Carbon Monoxide Concentration
Carbon monoxide concentrations indoors were 1 ppm for all readings. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentrations were 1 ppm for all collected readings.
Respirable Particulates (PMs pt
Respirable particulate concentrations* indoors ranged between 10 pg/m^ to 34 pg/m^. The average PM2.5 concentration for the entire school building was approximately 22 pg/m^. All of the indoor measurements were below the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter and the USEPA recommended concentration of 40 pgZm^ for sensitive individuals and children. The outdoor respirable particulate concentration measurements ranged between 79 pg/m^ to 90 g/m^ with an average of 85 pg/m^.
CITY_21MC100_006739744
NYC-WTC_000313851
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000369254
IAQ parameters with temperature, humidity, and gas readings.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313837
ATC indoor air quality measurements conducted June 10, 2002 for PS 89M per BOE request.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199027
Cover letter from ATC Associates submitting indoor air quality measurement results for PS89M collected on May 22, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369857
Indoor air quality report for PS/89M school, measurements collected May 22, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369881
ASME/BOE IAQ measurements report for P.S. 89M, May 24, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000394477
IAQ measurements collected April 25, 2002 at the referenced school.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000394489
Indoor air quality report for PS 89M with April 26, 2002 measurements.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000211016
Report of indoor air quality measurements conducted at P.S. 89M on June 10, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313861
ATC indoor air quality measurements collected June 12, 2002 for a NYC school.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369833
ATC report of IAQ measurements at P.S. 89M requested by BOE, dated May 21, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369266
ATC IAQ measurements collected June 12, 2002 for BOE evaluation.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000394514
IAQ measurements collected April 30, 2002 at the referenced school.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000369254
IAQ parameters with temperature, humidity, and gas readings.
Similar indexed content
NYC-WTC_000313837
ATC indoor air quality measurements conducted June 10, 2002 for PS 89M per BOE request.
Similar indexed content
Cover letter from ATC Associates submitting indoor air quality measurement results for PS89M collected on May 22, 2002.
Similar indexed content
NYC-WTC_000369857
Indoor air quality report for PS/89M school, measurements collected May 22, 2002.
Similar indexed content
NYC-WTC_000369881
ASME/BOE IAQ measurements report for P.S. 89M, May 24, 2002.
Similar indexed content