NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

PAH air sampling report, PS 89M, 2001-2002

Machine-extracted title · confidence 28%

Analytical report of polynuclear aromatic hydrocarbons in air at PS 89M, Jan 2002.

NYC-WTC_000313236–000313237
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan January 9, 2002 Air Sampling for PAHs Page 2 P. S. 89 (Manhattan) ATC Project No. 15-19125-0297

SAMPLING RESULTS

ATC submitted three (3) samples (one indoors, two outdoors) to PSC for analysis. PSC provided a lab blank. A copy of the laboratory report is provided in the Attachment. The minimum collection time for each sample was ten (10) hours. Samples were collected from locations specified by the parents association consultant. The locations of the samples were: Hallway by the Cafeteria, Playground (East) and the Roof by air intake.

Each sample was analyzed for sixteen (16) PAHs (See Attachment). Two PAHs were detected in one of the outdoor samples and indoors. The results are summarized in the table.

PAHs DETECTED Milligrams per cubic meter of air (mg/m^)

Roof by the air intake BDL BDL PAH-1 Playgroimd (east) 0.00028 0.00029 PAH-2 Hallway by Cafeteria 0.00045 0.00033 PAH-3 *BDL = Below Detection Limit

Naphthalene is an aromatic hydrocarbon used in the manufacture of plastics, dyes, resins and pesticides, 2- methylnaphthalene is found in some plastics and wood treatment chemicals. ATC has no specific information concerning possible sources of these PAHs in the school building.

The Occupational Safety and Health Administration (OSHA) has a Permissible Exposure Limit (PEL) for PAHs (benzene-soluble fraction of total particulates) of 0.2 mg/m^. This is approximately three orders of magnitude greater than the levels found in these samples, however the PEL is intended for industrial exposures.

It is our pleasure to provide these indoor environmental services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212 or 261.

Sincerely, J TC ASSOCIA TES INC.

James R. Cohn, CIH, CSP Regional Manager, Industrial Hygiene Division

Attachment

CITY_21MC1OO_OO3O3O7O7

NYC-WTC_000313237

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000313237Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →