Mr. Bernard P. Orlan July 1,2002 Air Sampling for Metals Page 2 Stuvvesant High School ATC Project No. 15-19125-0246

The blank-corrected Cr concentrations indoors were below the limit of detection (Sample #M1) and 0.000152 mg/m^ (Sample #M2). The blank-corrected outdoor (Sample #M3)) concentration was 0.000083 mg/m\

The blank-corrected Pb levels were below the limit of detection for all three samples.

Aluminum (Al) was detected in the bridge entrance lobby sample (Sample #M2) at 0.00113 mg/m^. Al was not found in the other two samples or in the blanks.

The established regulatory values for metals in air are intended for industrial workplace exposures and are not generally applicable to office/school settings. There are no standards for metals in indoor air in non-industrial situations.

The Environmental Protection Agency has recommended a screening level for hexavalent Cr (the more toxic form) of 0.6 micrograms per cubic meter of air (0.6 ug/m’) based on continuous exposure for one year. These samples were analyzed for total Cr.

The levels detected were below the EPA screening level for chromium.

The EPA has no guideline or screening level for aluminum in ambient air.

ATC appreciates the opportunity to provide this indoor air quality service to the BOE. Please call me at (212) 353-8280 extension 212 if you have any questions.

Sincerely, ATC Associates, Inc.

James PL. Cohn, CIH, CSP Regional Manager Industrial Hygiene Division

Attachment

CITY_21MC100_003046902

NYC-WTC_000312777

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000312777Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000406031

ATC report of air sampling for metals at Stuyvesant High School; April 2002.

Similar indexed content

NYC-WTC_000395384

Results of metals air sampling at Stuyvesant High School as requested by BOE.

Similar indexed content

NYC-WTC_000312674

ATC report of metals air sampling at Stuyvesant High School, June 2002.

Similar indexed content

Compare copies and versions →