NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Analytical results for ATC metals, 19125-0246, 02

Machine-extracted title · confidence 24%

Analytical results for metals analysis at ATC Associates, workorder R02040004.

NYC-WTC_000312743–000312744
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Apr 09 02 09:05a PSC 610-921-9GG7 p. 5

INDUSTRIAL HYGIENE ENVIRONMENTAL TESTING •EPANVLAP 101262-0 -NY DOiMUELAC 10903 ■NJDEP PA02D • AIHAACCREDITATION NO. 100439 ‘PA DEP 06-353 • CT DPHP1+023B •NCDENR599

ANALYTICAL SERVICES .Analytical Results for ATC Associates WorkOrder: R02040004 Client Reference: 19125-0246

Analyte Concentration Limit of Test Date Analyzed Detection Method /Analyst (ug) (mg/m’) : (ppm) (ug)

Client ID: M3 ATC-0327-SrY Lab ID: -03A Date Sampled:3/27/02 Matrix: Filter Air VoJ.(L): 960

----- Aluminum 2.87 0.00299 1 N7300 MCE 04/07/2002 AJB Cadmium <0.200 <0.000208 0.2 N7300 MCE 04/07/2002 AJB ■—-Chramium 0.767 0.000799 0.2 N730O MCE 04/07/2002 AJB Cobalt <0.100 <0.000104 0.1 N7300 MCE 04/07/2002 AJB Copper <0.200 <0.000208 0.2 N730O MCE 04/07/2002 AJB

Iron <2.00 <0.00208 2 N7300 MCE 04/07/2002 AJB Lead <0.300 <0.000312 0.3 N7300 MCE 04/07/2002 AJB Magnesium <1.30 <0.00135 1.3 N7300 MCE 04/07/2002 AJB

Manganese <0.300 <0.000312 0.3 N7300 MCE 04/07/2002 AJB

Molybdenum <1.00 <0.00104 1 N7300 MCE 04/07/2002 AJB

Nickel <0.200 <0.000208 0.2 N7300 MCE 04/07/2002 AJB

Zinc <0.500 <0.000521 0.5 N730O MCE 04/07/2002 AJB

Client ID: M4 ATC-0327-STY Lab ID: -04A Date Sampled: 3/27/02 Matrix: Filter Air Vol.(L): NA .------ Aluminum 2.43 1 N7300 MCE 04/07/2002 AJB Cadmium <0.200 0.2 N7300 MCE 04/07/2002 AJB __ Chromium 0.387. 0.2 N7300 MCE 04/07/2002 AJB

Cobalt <0.100 0.1 N7300 MCE 04/07/2002 AJB Copper <0.200 0.2 N7300 MCE 04/07/2002 AJB

Iron <2.00 2 N7300 MCE 04/07/2002 AJB

Lead <0.300 0.3 N7300 MCE 04/07/2002 AJB

Magnesium <1.30 1.3 N7300 MCE 04/07/2002 AJB

Manganese <0.300 0.3 N7300 MCE 04/07/2002 AJB Molybdenum <1.00 1 N7300 MCE 04/07/2002 AJB Nickel <0.200 0.2 N73O0 MCE 04/07/2002 AJB

Zinc <0.500 0.5 N7300 MCE 04/07/2002 AJB

(a) Analysis indicates possible breakthrough; back section result is greater than 0% of the front section result

General Notes; <: Less than the indicated limit of detection (LOD). —; Information not available or not applicable. Back sections were chocked and showed no significant breakthrough.

Page 2 of 2

CITY_21MC1OO_OO3O46865

NYC-WTC_000312744

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000312744Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →