Analytical Results for ATC VOCs, Nov 2001

Machine-extracted title · confidence 46%

Analytical results for hydrocarbons; ATC 208511, November 21–27, 2001.

NYC-WTC_000312564–000312566
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Hou 27 QI 0 5: 3 4 p PSC Raalytical Ssr~ vices e1GS213667 p . 3

page 3 of 3 27NDV01_U3S_;3_N'.26'_RF5

sea INDUSTRIAL HYGIENE ■ EPA/NVLAP 101232-C • AIHA ACCREDITATION NO. 100433 • NC DENR 599 ENVIRONMENTAL TESTING • NV DOH/NELAC 10903 • PA DEP OS-353 • NJ DEP 7702G • CT DPH PH-Q238

ANALYTICAL SERVICES Client; ATC Associates Project: 208511 RESULT UNITS CONCENTRATION UNITS METHOD

VOC-4 Blank Lab Sample; 1472448 - continued

Methylene chloride < 0,020 mg/sample 1005 Hexane < 0.020 mg/sample 1500 Chloroform < 0.020 mg/sample 1003 Methyl chloroform < 0.020 mg/sample 1003 total other A Hydrocarbons < 0.020 mg/sample 1500 Benzene < 0.020 mg/sample 1 501 1,2-Dichloroethane < 0.020 mg/sample 1003 Trichloroethylene c 0.020 mg/sample 1022 Toluene < 0.020 mg/sample 1 501 PCE (Tetrachloroefhene) < 0.020 mg/sample 1003 Chlorobenzene < 0.020 mg/sample 1003 Ethylbenzene c 0.020 mg/sample 1501 Styrene < 0.020 mg/sample 1 501 Cumene (Isopropylbenzene) < 0.020 mg/sample 1501 Xylenes, Total < 0.020 mg/sample 1501 total other B Hydrocarbons < 0.020 mg/sample 1501

Final sample concent rat ions calculated from air volLmes supplied on chain of custody. < Indicates less than the limit of quantitation.

4418 POTTSVILLE PIKE. READING, PENNSYLVANIA 19605 610-921-8633 FAX S10-921-9B67

CITY_21MC100_003046660 NYC-WTC_000312566

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000312566Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →