NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan December 14, 2001
Wipe Sampling for Dioxin Page 3
Stiivvesant High School (Manhattan) ATC Project No. 15-19125-0246
DIOXIN WIPE SAMPLE RESULTS
(2,3, 7, 8 TCDD EQUIVALENTS)
PiiiBlIB M
1
.14a , NOV. 20
0.00049 ng/sample 0.0014 ng/sample 0.0013 ng/sample
0.00019 ng/sample 0.0014 ng/sample 0.00044 ng/sample
0.0014 ng/sample 0.081 ng/sample 0.020 ng/sample
(AC #2) (AC #2) (AC#1)
Bl 0.00 ng/sample 0.00048 ng/sample 0.00027 ng/sample
ssOi
DISCUSSION
The concentrations on indoor surfaces ranged from 0.00019 ng/sample 0.0014 ng/sample. The
concentrations in the mixed air plenums ranged from 0.0014 ng/sample to 0.020 ng/sample. One
nanogram is equivalent to one part per billion (ppb) by weight. No standard has been established
for dioxin on indoor surfaces. The NYSDEC acceptable soil concentration is 0.0006 parts per
million (ppm) or 0.6 ppb. The levels found in these samples are well below the NYSDEC level.
It is not possible to determine when the 2, 3, 7, 8 - TCDD equivalents detected in these samples
were deposited. Dioxin samples were not collected from these locations prior to November 8^^.
It is our pleasure to provide these indoor environmental services to the NYC Board of Education.
If you have any questions about this report, please call (212) 353-8280, extension 212.
Sincerely,
.4 TC ASSOCIA TE^C.
James R. Cohn, CIH, CSP
Regional Manager
Industrial Hygiene Division
Attachments