NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street-Suite 200
Minneapolis. MN 55414
^ace Analytical_________
Method 8290 Analysis Results
Tel: 612-607-1700
Fax: 612- 607-6444
Client - ATC ASSOCIATES
Clients Sample ID ATC-0511-M833-DX3
Lab Sample ID 103536900
Filename U20522A_15
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 05/11/2002
ICAL Date 04/16/2002 Received 05/14/2002
CCal Fiiename(s) U20522A_03 & U20522A_18 Extracted 05/16/2002
Method Blank ID BLANK-1624 Analyzed 05/22/2002 21:59
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.00200 2,3.7,8-TCDF-13C 2.00 75
Total TCDF ND 0.00200 2,3,7,8-TCDD-13C 2.00 74
1,2,3,7.8-PeCDF-13C 2.00 88
2.3,7,8-TCDD ND 0.00280 A 2,3.4,7,8-PeCDF-13C 2.00 88
Total TCDD ND 0.00200 1,2,3.7,8-PeCDD-13C 2.00 88
1,2,3,4,7,8-HxCDF-13C 2.00 95
1.2,3.7,8-PeCDF ND 0.01000 1.2,3,6,7,8-HxCDF-13C 2.00 90
2,3,4,7,8-PeCDF ND 0.01000 2,3,4,6,7.8-HxCDF-13C 2.00 92
Total PeCDF ND 0.01000 1.2,3.7,8,9-HxCDF-13C 2.00 94
1.2,3,4,7,8-HxCDD-13C 2.00 92
1,2,3,7,8-PeCDD ND 0.01000 1,2.3,6,7,8-HxCDD-13C 2.00 83
Total PeCDD ND 0.01000 1.2,3,4,6,7,8-HpCDF-13C 2.00 81
1,2,3,4,7,8,9-HpCDF-13C 2.00 87
1,2,3.4,7,8-HxCDF ND 0.01000 1.2,3,4,6,7,8-HpCDD-13C 2.00 82
1,2,3,6.7,8-HxCDF ND 0.01000 OCDD-13C 4.00 92
2,3,4,6.7.8-HxCDF ND 0.01000
1,2,3,7,8,9-HxCDF ND 0.01000 1.2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.01000 1.2,3,7,8.9-HxCDD-13C 2.00 NA
1.2,3,4.7,8-HxCDD ND 0.01000 2,3.7.8-TCDD-37CI4 0.20 79
1,2.3,6,7,8-HxCDD ND 0.01000
1,2.3,7.8.9-HxCDD ND 0.01000
Total HxCDD ND 0.01000
1,2,3,4,6.7,8-HpCDF ND 0.01000 Total 2,3.7.8-TCDD
1.2.3.4.7,8.9-HpCDF ND 0.01000 Equivalence; 0.00 ng/m2
Total HpCDF ND 0.01000 (Using ITE Factors)
1,2,3,4.6,7,8-HpCDD ND 0.01000
Total HpCDD ND 0.01000
OCDF ND 0.02000
OCDD ND 0.02000
LRL = Lower Reporting Umit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC s Estimated Maximum Possible Concentration
E = PCDE Interference
A = Detection Limit based on signal-to-noisa measurement
S z Saturated signal
J = Concentration detected is below the calibration range NO = Not Detected
B = Less than 10 times higher than method blank level
NA = Not Applicable
P = Recovery outside ot target range
NC = Not Calculated
Nn = Value obtained from additional analysis * = See Oiscussion
Report No..... 02-1057487
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full.
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_003029278
NYC-WTC_000310980
OCR can misread numbers and units. Confirm readings against the page image before using them.