NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis. MN 55414
J^ace Analytical'_________ Tel; 612-607-1700
Far 612-607-6444
Method 8290 Analysis Results
Client - ATC ASSOCIATES
Clients Sample ID ATC-0511-M833-DX1
Lab Sample ID 103536884
Filename U20522A_13
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 05/11/2002
ICAL Date 04/16/2002 Received 05/14/2002
CCal Filename(s) U20522A_03 & U20522A_18 Extracted 05/16/2002
Method Blank ID BLANK-1624 Analyzed 05/22/2002 20:21
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/rn2 Standards Added Recovery
2,3,7,8-TCDF ND 0.00200 2,3,7,8-TCDF-13C 2.00 69
J Total TCDF ND 0.00200 2,3,7,8-TCDD-13C
1,2,3,7,8-PeCDF-13C
2.00
2.00
70
73
2.3,7,8-TCDD ND 0.00210 A 2.3,4,7,8-PeCDF-13C 2.00 73
Total TCDD 0.0021 0.00200 J 1,2.3.7,8-PeCDD-13C 2.00 72
J 1,2,3,7,8-PeCDF ND 0.01000
1,2.3.4,7.8-HxCDF-13C
1,2,3,6,7,8-HxCDF-13C
2.00
2.00
92
84
2,3,4,7,8-PeCDF ND 0.01000 2,3,4,6,7,8-HxCDF-13C 2.00 88
'1 Total PeCDF ND 0.01 obo 1,2,3,7,8,9-HxCDF-13C
1,2,3,4,7,8-HxCDD-13C
2.00
2.00
86
91
1,2,3,7,8-PeCDD ND 0.01000 1,2,3,6.7,8-HxCDD-13C 2.00 74
Total PeCDD ND 0.01000 1,2,3,4,6,7,8-HpCDF-13C 2.00 71
1,2,3,4,7,8,9-HpCDF-13C 2.00 73
1,2,3,4,7,8-HxCDF ND 0.01000 1,2,3,4,6.7,8-HpCDD-13C 2.00 71
1,2,3,6,7,8-HxCDF ND 0.01000 OCDD-13C 4.00 77
2,3,4.6,7,8-HxCDF ND 0.01000
1,2,3,7,8,9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.01000 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1.2,3,4,7,8-HxCDD ND 0.01000 2,3,7,8-TCDD-37CI4 0.20 79
1,2,3,6,7,8-HxCDD ND 0.01000
1.2,3.7,8,9-HxCDD ND 0.01000
Total HxCDD ND 0.01000
1,2,3,4,6.7,8-HpCDF ND 0.01000 Total 2,3,7,8-TCDD
i 1,2,3,4,7.8.9-HpCDF
Total HpCDF
ND
ND
0.01000
0.01000
Equivalence: 0.00 ng/m2
(Using ITE Factors)
1,2,3,4,6.7,8-HpCDD ND 0.01000
Total HpCDD ND 0.01000
OCDF ND 0.02000
OCDD ND 0.02000
LRL 3 Lower Reporting Limit
Cone = Concentration (Totals include 2.3,7,8-substituted isomers) t = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-nolse measurement S = Saturated signal
J = Concentration detected is below the calibration range ND X Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicabie
P = Recovery outside of target range
NC X Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1057487
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Paco Analytical Services, Inc.
CITY_21MC1OO_OO3O29276
NYC-WTC_000310978
OCR can misread numbers and units. Confirm readings against the page image before using them.