NYC-WTC_000310992
Appendix B; Report of Laboratory Analysis for NYC-WTC sample CITY_21MC100_012155622.
3 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗Appendix B of Pace Analytical report for NYC WTC samples.
NYC-WTC_000310884–000310891OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Paco Analytical ou. wiwo....... I7nn = m STe?' - 2?? ViftneaK'liSi, Ml' f Sf’-'-
^ace Analytical_________ Method 8290 Analysis Results “lii •il2-(j0'’-17C0 Fax' 612- 607-6444
Client - ATC ASSOCIATES I Client's Sample ID ATC-0427-M833-DX2 Lab Sample ID 103499844 Filename F20507A_18 Injected By BAL Total Amount Extracted 1 m2 Matrix WIPE % Moisture NA Dilution NA Dry Weight Extracted NA Collected 04/27/2002 ICAL Date 05/04/2002 Received 04/30/2002 CCal Filename(s) F20507A_06 & F20507A_22 Extracted 05/03/2002 Method Blank ID BLANK-1609 Analyzed 05/08/2002 00:43 Native Cone EMPC LRL Internal ng's Percent Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery 2,3,7.8-TCDF ND — 0.00200 2.3,7,8-TCDF-13C 2.00 79 Total TCDF 0.0025 — 0.00200 J 2,3,7,8-TCDD-13C 2.00 74 1,2,3,7,8-PeCDF-13C 2.00 60 2.3,7,8-TCDD ND 0.00200 2,3,4.7,8-PeCDF-13C 2.00 58 Total TCDD 0.0150 0.00200 1,2,3,7,8-PeCDD-13C 2.00 60 1,2.3,4,7.8-HxCDF-13C 2.00 97 1,2,3,7,8-PeCDF ND 0.01000 1,2.3.6,7,8-HxCDF-13C 2.00 79 2.3,4,7,8-PeCDF ND 0.01000 2,3.4,6,7.8-HxCDF-13C 2.00 87 Total PeCDF ND 0.01000 1.2,3,7,8,9-HxCDF-13C 2.00 87 1,2,3.4,7,8-HxCDD-13C 2.00 92 1,2,3,7,8-PeCDD ND 0.01000 1,2,3,6,7,8-HxCDD-13C 2.00 92 Total PeCDD ND 0.01000 1,2,3,4,6,7,8-HpCDF-13C 2.00 81 1,2,3.4.7,8,9-HpCDF-13C 2.00 72 1,2,3,4,7,8-HxCDF ND 0.01000 1.2,3,4,6,7,8-HpCDD-13C 2.00 76 1,2,3,6,7,8-HxCDF ND 0.01000 OCDD-13C 4.00 63 2,3,4,6,7,8-HxCDF ND 0.01000 1,2,3,7,8,9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA Total HxCDF ND 0.01000 1,2,3,7,8,9-HxCDD-13C 2.00 NA 1,2,3,4,7,8-HxCDD ND 0.01000 2,3.7,8-TCDD-37CI4 0.20 82 1,2.3,6,7,8-HxCDD ND 0.01000 1.2,3,7,8,9-HxCDD ND 0.01000 Total HxCDD ND 0.01000
1,2,3,4,6,7,8-HpCDF ND 0.01000 Total 2.3.7,8-TCDD 1,2,3.4,7.8,9-HpCDF ND 0.01000 Equivalence: 0.000078 ng/m2 Total HpCDF ND 0.01000 (Using ITE Factors) 1,2,3,4,6,7.8-HpCDD ND 0.01000 Total HpCDD ND 0.01000 OCDF ND 0.02000 OCDD 0.0780 0.02000 J LRL = Lower Reporting Limit Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference EMPC = Estimated Maximum Possible Concentration E = PCDE Interference A = Detection Limit based on signal-to-noise measurement S = Saturated signal J = Concentration detected is below the calibration range NO = Not Detected B = Less than 10 times higher than method blank level NA = Not Applicable P = Recovery outside of target range NC = Not Calculated Nn = Value obtained Irom additional analysis ' = Soo Discussion Report No.... 02-1056896
REPORT OF LABORATORY ANALYSIS This report shall not bo reproduced, except in full. without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_003029175
NYC-WTC_000310887
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000310992
Appendix B; Report of Laboratory Analysis for NYC-WTC sample CITY_21MC100_012155622.
3 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310914
Appendix B of Pace Analytical report for NYC WTC samples.
4 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310905
Appendix B of Pace Analytical report for NYC WTC samples.
4 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310927
Appendix B of Pace Analytical report for NYC WTC samples.
3 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000404706
BAL matrix wipe sample results, 05/2002.
3 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310894
Appendix B of Pace Analytical report for NYC WTC samples.
3 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250184
Pace Analytical Appendix B report of laboratory analysis.
4 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310952
Appendix B of Pace Analytical report for NYC WTC samples.
3 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383467
Laboratory results for wipe samples (BAL) using Method 8290, client ATC.
3 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407088
Laboratory report pages listing methods and sample IDs for Stuyvesant HS analyses.
5 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000404672
ATC wipe sample analysis results for BAL matrix, 2002.
4 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000240715
Laboratory analysis report appendix; data for NYC-WTC sample set; confidential.
4 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000351210
Lab report for metal analysis in air sample from ATC, 08/23/2002.
Similarity score 0.971 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310905
Appendix B of Pace Analytical report for NYC WTC samples.
Similarity score 0.971 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000405225
Lab results for WIPE sample analyzed via ATC methods with dates.
Similarity score 0.969 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000240174
Lab analysis results for wipe sample (WIPE) with lab IDs.
Similarity score 0.969 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000372628
Analytical report for ATC-STY-DX8 dust sample (April–May 2002).
Similarity score 0.968 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000396879
Analytical results report for ATC wipe sample, Method 8290, with dates in 2002.
Similarity score 0.968 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Appendix B; Report of Laboratory Analysis for NYC-WTC sample CITY_21MC100_012155622.
Similar indexed content
Appendix B of Pace Analytical report for NYC WTC samples.
Similar indexed content
Appendix B of Pace Analytical report for NYC WTC samples.
Similar indexed content
Appendix B of Pace Analytical report for NYC WTC samples.
Similar indexed content
NYC-WTC_000404706
BAL matrix wipe sample results, 05/2002.
Similar indexed content