NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Real-time air monitoring report, BOE, 104 East 25th St, Mar

Machine-extracted title · confidence 41%

ATC report for March 21, 2002 monitor locations and results of respirable particulates.

NYC-WTC_000310319–000310320
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan March 22, 2002 Respirable Particulate Monitoring Page 2 Various Locations/Manhattan ATC Project No. 15-19125-0314

TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED*

Respirable 65 micrograms per cubic Peirticulates meter of air (pg/m3) 24 USEPA NPAAQS (PM2.5) hour average Respirable USEPA recommendation Particulates 40 pg/m3 24 hour average for children/ sensitive (PM2.5) individuals USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard

REAL-TIME SAMPLING RESULTS

Thirty-two (32) indoor and thirty-four (34) outdoor respirable particulates measurements* were collected from thirty school locations in Manhattan, ranging from West 11* Street to East 33''^ Street. The measurements were made from 5:35 A.M. to 4:25 P.M. The lAQ field report forms are provided as the Attachment.

The outdoor PM2.5 concentrations ranged from 38 pg/m^ to 65 pg/m^. The indoor concentrations ranged from 15 pg/m^ to 41 pg/m^. None of the outdoor or indoor readings were above the NPAAQS of 65 pg/m^. Two (2) of the indoor and thirty (30) of the outdoor measurements were above the EPA recommended guideline for children and sensitive individuals of 40 pg/m^.

These measurements were instantaneous readings, the NPAAQS and the recommendation for children are 24-hour averages.

CONCLUSION

Based on our measurements, none of the outdoor or the indoor readings were above the NPAAQS of 65 pg/m3. Two (2) of the indoor and thirty (30) of the outdoor measurements were above the EPA recommended guideline for children and sensitive individuals of 40 pg/m3.

It is our pleasure to provide these air qutdity consultative services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212 or 211.

Sincerely, ATC ASSOCIATES INC.

kjfiannis Efstathiou Senior Project Manager

Attachment

CITY_21MC100_003043953

NYC-WTC_000310320

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000310320Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000196911

Report from ATC Associates detailing real-time air monitoring of respirable particulates at NYC Board of Education schools on April 9, 2002.

Similar indexed content

Compare copies and versions →