Mr. Bernard P. Orlan March 21, 2002 Respirable Particulate Monitoring Page 2 Various Lxjcations/Manhattan ATCPrqiectNq^l5-1912520314

TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED*

Respirable 65 micrograms per cubic n 1 Particulates meter of air (pg/m.3) 24 USEPA NPAAQS (PMa.s) hour average Respirable USEPA recommendation Particulates 40 |xg/m3 24 hour average for children/sensitive (PM2.5) individuals USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard

REAL-TIME SAMPLING RESULTS

A total of sixty (66) respirable particulates measurements* were collected from twenty-nine locations in Manhattan, ranging from West 11^** Street to East 33'^> Street. The measurements were made from 5:30 A.M. to 4:35 P.M. The lAQ field report forms are provided as the Attachment.

The outdoor PM2 5 concentrations ranged from 13 pg/m’ to 31 pg/m\ The indoor concentrations ranged fi-om 9 pg/m’ to 28 pg/m\ None of the indoor or outdoor readings were above the NPAAQS of 65 pg/m’ or above the EPA recommended guideline for children and sensitive individuals of 40pg/m\

• These measurements were instantaneous readings, the NPAAQS and the recommendation for children are 24-hour averages.

CONCLUSION

Based on our measurements, none of the indoor or outdoor readings were above the NPAAQS of 65 qg/m^ or above the EPA recommended guideline for children and sensitive individuals of 40 pg/m^.

It is our pleasure to provide these air quality consultative services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212 or 211.

Sincerely, ATC ASSOCIATES INC.

Yiannis Efstathiou James R. Cohn, CIH, CSP Senior Project Manager Rejponal Manager Industrial Hygiene Division Attachment

CITY_21MC100_003043943

NYC-WTC_000310318

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000310318Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →