NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan April 23, 2002 Respirable Particulate Monitoring Page 2 Various Locations/Manhattan ATC Project No. 15-19125-0314

TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED*

£______ Mia uwfellijRrli Respirable 65 micrograms per cubic Particulates meter of air (pg/m3) 24 USEPA NPAAQS (PM2.5) hour average Respirable USEPA recommendation Particulates 40 for children/sensitive 24 hour average (PM2.5) individuals USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard

REAL-TIME SAMPLING RESULTS

Thirty (30) indoor and thirty-three (33) outdoor respirable particulates measurements* were collected from thirty-two (32) school locations in Manhattan, ranging from West 11^ Street to East 33’' * Street. The measurements were made from 5:45 A.M. to 4:37 P.M. The lAQ field report forms are provided as the Attachment.

The outdoor PM2.5 concentrations ranged from 28 gg/m^ to 63 pg/m^ with an average of 42 ug/m^. All of the outdoor readings were below the NPAAQS recommended guidelines of 65 pg/m^ 24-hour average concentration of particulate matter 2,5 micrometers or less in aerodynamic diameter. Sixteen (16) of the thirty-three (33) instantaneous outside readings were above the USEPA recommended guideline of 40 pg/m^ for children and sensitive individuals. The indoor concentrations ranged from 12 pg/m^ to 33 pg/m^ with an average of 25 ug/m^. All of the indoor readings were below the NPAAQS of 65 pg/m3 24-hour average concentration of particulate matter 2,5 micrometers or less in aerodynamic diameter and the EPA recommended guideline for children and sensitive individuals of 40 pg/m3.

* These measurements were instantaneous readings, the NPAAQS and the recommendation for children are 24-hour averages.

CONCLUSION

Based on our measurements, all of the outdoor readings were below the NPAAQS recommended guidelines of 65 gg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. Sixteen (16) of the thirty-three (33) instantaneous outside readings were above the USEPA recommended guideline of 40 (ig/m^ for children and sensitive individuals. All of the indoor readings were below the NPAAQS of 65 gg/m^ 24- hour average concentration of particulate matter 2.5 micrometers or less in aerod5mamic diameter and the EPA recommended guideline for children and sensitive individuals of 40 ng/m\

CITY_21MC1OO_OO3O43482

NYC-WTC_000310248

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000310248Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →