Mr. Bernard P, Orlan March 15, 2002 Respirable Particulate Monitoring Page 2 Various Locations/Manhattan ATC Project No. 15-19125-0314 r TARGET GUIDELINES FOR AIR QUALITY PARAB^^SEVAUJAraD*

I ' Respirable 65 micrograms per cubic Particulates meter of air (pg/m^) 24 USEPA NPAAQS (PMa.s) hour average Respirable USEPA recommendation Particulates 40 gg/m3 24 hour average for children/sensitive (PM2.5) individuals USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard

REAL-TIME SAMPLING RESULTS

Thirty-two (32) indoor and thirty-eight (38) outdoor respirable particulates measurements* were collected from thirty-four school locations in Manhattan, ranging from West 11* Street to East SSrd Street. The measurements were made from 5:35 A.M. to 4:45 P.M. The lAQ field report forms are provided as the Attachment.

The outdoor PMzs concentrations ranged from 44 pg/m^ to 110 pg/m^. The indoor concentrations ranged from 19 pg/m^ to 77 pg/m^. Twenty-one (21) of the outdoor and three (3) of the indoor readings were above the NPAAQS of 65 pg/ra^. Twenty-two (22) of the indoor and thirty-eight (38) of the outdoor measurements were above the EPA recommended guideline for children and sensitive individuals of 40 pg/m\

* These measurements were instantaneous readings, the NPAAQS and the recommendation for children are 24-hour averages.

CONCLUSION

Based on our measurements, twenty-one (21) of the outdoor and three (3) of the indoor readings were above the NPAAQS of 65 (rg/m^. Twenty-two (22) of the indoor and thirty-eight (38) of the outdoor measurements were above the EPA recommended guideline for children and sensitive individuals of 40 (ig/m^.

It is our pleasure to provide these air quality consultative services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212 or 211.

Sincerely, ATC ASSOCIATES INC. Reviewed by:

iannis Efstathiou James R. Cohn, CIH, CSP Project Manager Regional Manager, Industrial Hygiene Division

Attachment

CITY_21MC100_003028714

NYC-WTC_000310212

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000310212Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000196911

Report from ATC Associates detailing real-time air monitoring of respirable particulates at NYC Board of Education schools on April 9, 2002.

Similar indexed content

Compare copies and versions →