NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan March 11, 2002 Respirable Particulate Monitoring Page 2 Various Locations /Manhattan ATC Project No. 15-19125-0314 TARGET GTUDELINES FOR AIR QUALITY PARAMETERS EVALUATED* 1 iisMik 515 Respirable 65 micrograms per cubic Particulates meter of air (pg/m^) 24 USEPA NPAAQS (PM2.5) hour average Respirable USEPA recommendation Particulates 40 (xg/m^ 24 hour average for children/sensitive (PM2.5) individuals USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard
REAL-TIME SAMPLING RESULTS
Thirty (30) indoor and thirty-nine (39) outdoor respirable particulates measurements* were collected from thirty-two school locations in Manhattan, ranging from West 11*** Street to East 33^^ street. The measurements were made from 5:35 A.M. to 4:45 P.M. The lAQ field report forms are provided as the Attachment,
The outdoor PM2 5 concentrations ranged from 50 pg/m^ to 208 pg/mt The indoor concentrations ranged from 24 pg/m^ to 134 pg/m^. Twenty-five (25) of the indoor readings and thirty-eight (38) outdoor readings were above the NPAAQS of 65 pg/m^. Twenty-nine (21) of the indoor and all of the outdoor instantaneous measurements were above the EPA recommended guideline for children and sensitive individuals of 40 pg/m^.
★ These measurements were instantaneous readings, the NPAAQS and the recommendation for children are 24-hour averages.
CONCLUSION
Based on our measurements, twenty-five (25) of the indoor readings and thirty eight (38) outdoor readings were above the NPAAQS of 65 pg/m^. Twenty-nine (21) of the indoor and all of the outdoor instantaneous measurements were above the EPA recommended guideline for children and sensitive individuals of 40 pg/m3.
It is our pleasure to provide these air quality consultative services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212 or 211.
Sincerely, ATe ASSOCIATES INC. Reviewed by:
^nel ■James R. Cohn, CIH, CSP Senior Rmject Manager Regional Manager, Industrial Hygiene Division^
Attachment
CITY_21MC100_003028674
NYC-WTC_000310204
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000310201
ATC report of respirable particulates monitoring at multiple NYC BOE locations in Mar 2002.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310209
ATC report of respirable particulates monitoring at multiple NYC BOE locations in Mar 2002.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310301
ATC reporting respirable particulates measured March 7–8, 2002 for BOE sites.
9 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315701
Real-time particulate monitoring at multiple locations for BOE.
9 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310303
ATC report of real-time respirable particulates monitoring at multiple NYC BOE locations in March 2002.
9 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310337
ATC report of April 16, 2002 respirable particulates monitoring at multiple sites.
9 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000196917
Report from ATC Associates detailing real-time air monitoring of respirable particulates at NYC Board of Education schools on April 11, 2002.
9 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310234
Report of real-time air monitoring of respirable particulates conducted April 15, 2002 for the BOE.
9 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310319
ATC report for March 21, 2002 monitor locations and results of respirable particulates.
9 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310315
ATC report of respirable particulates monitoring conducted March 19, 2002 at multiple locations.
9 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310287
ATC monitoring results for BOE sites on Feb 26, 2002.
9 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310274
ATC report of respirable particulates collected Feb 8, 2002 for BOE sites.
9 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000310201
ATC report of respirable particulates monitoring at multiple NYC BOE locations in Mar 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353090
ATC report of respirable particulates monitoring at multiple NYC BOE locations, Feb 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310337
ATC report of April 16, 2002 respirable particulates monitoring at multiple sites.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310209
ATC report of respirable particulates monitoring at multiple NYC BOE locations in Mar 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000196917
Report from ATC Associates detailing real-time air monitoring of respirable particulates at NYC Board of Education schools on April 11, 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310301
ATC reporting respirable particulates measured March 7–8, 2002 for BOE sites.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000310201
ATC report of respirable particulates monitoring at multiple NYC BOE locations in Mar 2002.
Similar indexed content
NYC-WTC_000310209
ATC report of respirable particulates monitoring at multiple NYC BOE locations in Mar 2002.
Similar indexed content
NYC-WTC_000310301
ATC reporting respirable particulates measured March 7–8, 2002 for BOE sites.
Similar indexed content
NYC-WTC_000315701
Real-time particulate monitoring at multiple locations for BOE.
Similar indexed content
NYC-WTC_000310303
ATC report of real-time respirable particulates monitoring at multiple NYC BOE locations in March 2002.
Similar indexed content