Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 'ace Analytical’ Minneapolis, MN 55414 Phone 612.607 1700 ' www.pacelabs.com Fax 612.607 6444 TABLE 1. 2,3.7,8-TCDD Equivalency Factors (TEFs) for the Polychlorinated Dibenzo-p-dioxins and Dibenzofurans

Number Compound(s) TEF

1 2,3,7,8-TCDD 1.00 ' 2 1,2,3,7,8-PeCDD 0.50 3 1,2,3,6,7,8-HxCDD 0.1 4 1,2,3,7,8,9-HxCDD 0.1 5 1,2,3,4,7,8-HxCDD 0.1 6 1,2,3,4,6,7,8-HpCDD 0.01 ; 7 OCDD 0.001 V 8 * Total - TCDD 0.0 9 * Total - PeCDD 0.0 10 * Total - HxCDD 0.0 . 11 * Total - HpCDD 0.0

12 2,3,7,8-TCDF 0.10 13 1,2,3,7,8-PeCDF 0.05 14 2,3,4,7,8-PeCDF 0.5 15 1,2,3,6,7,8-HxCDF 0.1 16 1,2,3,7,8,9-HxCDF 0.1 17 1,2,3,4,7,8-HxCDF 0.1 18 2,3,4,6,7,8-HxCDF 0.1 19 1,2,3,4,6,7,8-HpCDF 0.01 20 1,2,3,4,7,8,9-HpCDF 0.01 21 OCDF 0.001 22 * Total - TCDF 0.0 23 * Total ' PeCDF 0.0 24 * Total - HxCDF 0.0 25 * Total - HpCDF 0.0

J *Excluding the 2,3,7,8-substituted congeners.

Reference: 1 989 ITEFs

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in toll, without the written consent of Pace Analytical Services, Inc.

mefeci CITY_21MC100_003043000

NYC-WTC_000309911

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000309911Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000309888

Laboratory analysis report package from Pace Analytical for project samples.

Similar indexed content

Compare copies and versions →