Method 8290 Analysis Results
Client - ATC ASSOCIATES
Client's Sample ID ATC-0827-1M-DX3
Lab Sample ID 103815270
Filename U21010B_12
Injected By MRO
Total Amount Extracted 1.00 m2 Matrix WIPE
% Moisture NA Dilution NA
"1 Dry Weight Extracted NA Collected 08/27/2002
ICAL Date 08/06/2002 Received 08/28/2002
CCal Filename(s) U21010A_14&U21010B_16 Extracted 09/29/2002
Method Blank ID BLANK-2231 Analyzed 10/11/2002 04:40
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.00200 2,3,7,8-TCDF-13C 2.00 92
Total TCDF 0.0021 0.00200 J 2,3,7,8-TCDD-13C 2.00 87
1,2,3.7,8-PeCDF-13C 2.00 92
2,3,7.8-TCDD ND 0.00200 2,3.4,7,8-PeCDF-13C 2.00 95
■)
Total TCDD 0.0190 0.00200 1,2,3,7.8-PeCDD-13C 2.00 89
1,2,3,4,7,8-HxCDF-13C 2.00 100
J 1,2,3,7,8-PeCDF ND 0.01000 1,2,3,6,7,8-HxCDF-13C 2.00 108
2,3,4,7,8-PeCDF ND 0.01000 2,3.4.6,7,8-HxCDF-13C 2.00 105
Total PeCDF ND 0.01000 1,2,3,7,8,9-HxCDF-13C 2.00 104
1,2,3,4,7,8-HxCDD-13C 2.00 112
1,2,3,7,8-PeCDD ND 0.01000 1,2,3,6,7,8-HxCDD-13C 2.00 100
Total PeCDD ND 0.01000 1,2,3,4,6,7,8-HpCDF-13C 2.00 101
1,2,3,4,7,8,9-HpCDF-13C . 2.00 93
1,2,3,4,7,8-HxCDF ND 0.01000 1,2,3,4,6,7,8-HpCDD-13C 2.00 " 94
1,2,3,6,7.8-HxCDF ND 0.01000 OCDD-13C 4.00 73
2,3,4,6,7,8-HxCDF ND 0.01000
1,2,3,7,8,9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.01000 1,2,3,7.8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.01000 2,3.7,8-TCDD-37CI4 0.20 84
1,2,3,6,7,8-HxCDD ND 0.01000
1,2,3,7,8,9-HxCDD ND 0.01000
Total HxCDD ND 0.01000
1,2,3,4,6,7.8-HpCDF ND 0.01000 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.01000 Equivalence: 0.000045 ng/m2
Total HpCDF ND 0.01000 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD ND 0.01000
Total HpCDD ND 0.01000
J.
OCDF ND 0.02000
OCDD 0.0450 0.02000 J
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentraton detected is below the calibration range ND = Not Detected '
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 1061946
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.