NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan January 15, 2002
Air Sampling for Mercury Page 2
Stuvvesant Hiah School ATCProiectNo. 15-19125-0246
TABLE 2
Airborne Mercury (Hg) Concentrations
January 9, 2002
;io
Hg-1 0.040 96 0.000417
1“ Floor Main Lobby
Hg^ 0.0350 96 0.000365
2”'’ floor bridge lobby
H?3 0.0360 96 0.000375
Roof
0.0390
Blank
* milligrams per cubic meter of air / Not b ank corrected
After the Hg levels in the blanks are subtracted, the maximum concentrations in the indoor
samples drop to 0.000010 mg/m^ on both days. The outdoor levels drop to 0.000010 mg/m’ on
January 3"* and below the limit of detection on January 9*
There are currently no federal ambient air standards for mercury. The Occupational Safety and
Health Administration ’s (OSHA) Permissible Exposure Limit (PEL) for mercury is l.Omg/lOm’
(O.lmg/m^). This is considerably above the levels that were detected or that would otherwise be
expected in a school or office and it is not an applicable standard.
ATC appreciates the opportunity to provide this indoor air quality service to the BOE. Please call
me at (212) 353-8280 extension 212 if you have any questions.
Sincerely,
ATC Associates, Inc.
James R. Cohn, CIH, CSP
Regional Manager
Industrial Hygiene Division
Attachment
CITY_21MC100_003056466
NYC-WTC_000308667