Mr. Bernard P. Orlan January 4, 2002
Wipe Sampling for PCBs Page 2
Stuyvesant High School (Manhattan) ATC Project No. 15-19125-0246
WIPE SAMPLING RESULTS
ATC submitted three samples for PCBs (plus one blank) for each sampling day to PSC for
analysis. A copy of the laboratory report is provided in Attachment 1. Samples were taken from
areas specified by the parents association consultant. The sample area for each wipe sample was
100 square centimeters (lOOcm^). The areas sampled were;
December 20, 2001 December 26, 2001
1 st floor main entrance hallway - Column 1®*^ floor main entrance hallway - wall
2’td floor bridge entrance - wall 2'1^ floor bridge entrance hallway - wall
AC#2 mixed air plenum - floor AC#1 mixed air plenum - floor
Each sample was analyzed for seven PCB compounds with differing percentages of chlorine.
The PCB results of all samples were below the reporting limits (2.0 micrograms/sample) on
both sampling days. The same level was found in the blanks.
Currently, the Environmental Protection Agency spill clean-up standard for PCBs on non-porous
surfaces is 10 micrograms per 100 square centimeters or less (<10ug/100cm2) as stated in 40
CFR761.
It is our pleasure to provide these indoor environmental services to the New York City Board of
Education. If you have any questions about this report, please call (212) 353-8280, extension
212 01-261.