Respirable Silica: The overwhelming majority of 861 silica samples (excluding bulk and blank

samples) show no detectable levels of airborne silica. However, 54 exposures

exceeded the PEL. The highest sample result was approximately twenty-one

times the OSHA limit (jack hammering concrete 16 feet below grade). The

other elevated exposures were approximately one to fourteen times the OSHA

limit. These exposures occurred during: 1) pre-drilling /slurry wall 2) jack

hammering, 3) rubble removal and loading operations near the Winter Garden;

4) during the breaking up of concrete in the pit; 5) while drilling the concrete

slurry wall, 6) flagging operations in pit, and 7) while chipping concrete with

power tools during demolition activities at 7 WTC’s parking garage. Most of the work areas where apparent overexposures to silica occurred were in the

rubble pile/pit; an area where OSHA continues to encourage the use of

respiratory protection.

Organic

Compounds; OSHA has taken a total of 652 samples (excluding bulk and blank samples)

for organic compounds such as acetaldehyde, acrolein, acrylonitrile, benzene,

2-butanone, carbofurans, dioxin, PCBs, ethyl benzene, formaldehyde. Freon

R-22 (chlorodiflouromethane), hexone, isocyanates (e.g. MDI, TDI),

perchloroethylene, polynuclear aromatics, phosgene, styrene, toluene, 1-3

butadiene, trichloroethylene, vinyl chloride, glutaraldehyde, and xylene.

Screening samples initially showed elevated levels of some organic chemicals resulting from the fires burning in the rubble pile. Subsequent personal and

area samples show worker exposure levels to be below OSHA limits.

However, one personal sample result for a benzene sample taken was found to

be at the 8-hr. OSHA Allowable Limit concentration of 1 ppm. This was found

on a backhoe operator moving debris on 10/7/01. See information below for

the specific counts in regards to polynuclear aromatics, Freon R-22, phosgene

and dioxin.

Dioxins: OSHA has taken 10 dioxin samples (excluding blanks) in the plume over hot

spots in (and around the perimeter of) the mbble pile. Dioxin levels detected

Page 2 of 4

CITY_21MC100_008956050

NYC-WTC_000308275

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000308275Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →