Fax=2122599815 Oct 31 2001 10=13 P.02

OSNA SAMPLING RESULTS SUMMARY AS OF 1Q/24 Asbestos; A total of 587 air monitoring samples for asbestos have been taken. From 9/13 -9/22,177 samples were taken in the financial district. They were taken on OSHA personnel as they walked wi^n certain predetermined zones. Results revealed asbestos concentrations rangiftg from ND to .037 i/cc., well below OSHA’s permissible exposure limit (PEL) of .1 f/cc. Aftcr 9/22, sampling focused on the rubble pile and those workers working on or immediately next to it. 53 of 410 samples exceeded OSHA’s limit via PCM analysis. However, imon further analysis using discriminating counting methods and/or TEM analysis, the number of asbestos fibers found dropped dramatically to below detectable levels or well below .1 f/cc. Carbon Monoxide: im losure limit Noise: OSHA has been conducting noise monitoring in the rubble pile. Twelve personal samples have been conducted on employees perfonning (or working near) various operations such as jack hammering. Employee’s exposure to the noise range from 80.6 dBA to 89 dBA, OSHA s permissible noise exposure for construction is 90 dBA Respirable Silica; As of October 22, the overwhelming majority of the 189 silica samples show no detectable levels of airborne silica. The hipest sample result was approximately twice the OSHA limit, whereas the next highest level was less than half of this limit. Both of these levels were found on personnel working in the rubble pile; an area where OSHA continues to encourage the use of respiratory protection. Volatile Organic Compounds: OSHA has taken 173 samples for (VOCs) such as acetaldehyde, acrylonitrile, acrolein, benzene, 2-butanonc, chlorodmhenyl (PCB), ethyl benzene, formaldehyde, hexone, isocyanates e.g. (MDI)( HDI), perchloroethylene, styrene, toluene, trichloroethylene, vinyl chloride and xylene. Screening samples initially showed elevated levels of some organic chemicals resulting from the fires burning in the rubble pile. Subsequent personal and area samples show worker exposure levels to be below OSHA limits. However, one personal sample result for benzene was found to be at the 8hr OSHA Allowable Limit concentration of Ippm. This was found on a backhoe operator moving debris. Oxides of Nitrogen; Sampling on employees manning the truck wash stations found no detectable levels of nitrous or nitric oxide Metals; As of 10/19 OSHA has taken 261 air samples to monitor worker exposures to dusts, fumes, oxides, and other compounds of mexals such as antunony, beryUium, chromium, cobalt, copper, iron, lead, manganese, molybdenum, nickel, vanadium, zinc, cadmium, magnesium, arsenic, and mercury. Results from these samples are generally well below the applicable OSHA limits. However, torch cutting and burning structural steer at the pile have resulted in instances of overexposwes as follows; copper (6); iron oxide I (6); lead (1); and cadmium (3), Accordingly, OSHA is recommending that workers engaged in these operations wear appropriate respiratory protection.

CITY_21MC100_008980008

NYC-WTC_000308196

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000308196Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →