Proposed VOC air sampling plan, WTC, 10/23/01

Machine-extracted title · confidence 40%

Draft VOC plan to sample aldehydes, ketones, phenols, and particulates near WTC.

NYC-WTC_000306696–000306701
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Aldehydes

ANALYTE 1 Formaldehyde 2 Acetaldehyde___________ 3 Acrolein 4 Acetone 5 Propionaldehyde______ _ 6 Crotonaldehyde_______ _ 2 Butyraldehyde__________ 8 Benzaldehyde 9 Isovaleraldehyde________ Valeraldehyde__________ 11 O, M, and P - tolualdehyde 12 Hexaldehyde___________ 13 2,5-dimethylbenzaldehyde

The Bronx Asthma study (Jan 1999-Nov 2000) included the above analytes using the same methodology. That dataset will provide a good reference for the aldehyde data. Additionally, the EPA database and the EPA base database have formaldehyde results. Aldehyde air levels will be evaluated with available health-based air comparison values for acute, intermediate and long-term exposure. Also, odor and irritancy values will be considered when available.

Acids

__________________ ANALYTE____________________ 1 Hydrochloric acid (as per denuder system)_______________ 2 ■3 Sulfuric acid (as per denuder system)____________________ PM 2.5 Acidity-pH of the filter (aerosol as per denuder system) 4 PM2.5 Sulfate on the filter (aerosol as per denuder system) 5 HONO__________________________________________ 6 HNO3___________________________________________ 7 Inorganic Acids (as per NIOSH Method 7903) Sulfuric, Nitric and Hydrochloric acids

The pH of the PM2.5 aerosol and the sulfate concentration of the aerosol were measured for the entire Bronx Asthma Study (Jan 1999 -Nov 2000) period. HCl, HONO, and HNO3 were measured during the Bronx Asthma Study from July 1999 to June 2000. The Bronx asthma study included sampling in Manhattan and these data will be used as a reference. NIOSH Method 7903 (sulfuric acid) has been used in monitoring the personnel working at the world trade disaster. These data will also be used as a reference. Most of the data from the NIOSH methodology has shown just trace amounts, which is probably because the detection limit for this method is high. Levels of acids in air will be evaluated with available health-based air comparison values for acute, intermediate and long- term exposure. Also, odor and irritancy values will be considered when available.

CITY_DEP_WORBY_CANNATA_SUBP_000032643

NYC-WTC_000306700

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000306700Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →