NYC 9/11 Public Portal Document
NOU-09-2001 18518 ENUIROMENTAL DISEASE PREU 212 788 4299 P. 40/42
DRAFT (Version 21), November 8,2001****
H • Compare results to representative background.** • Compare results to represci
250 I • Identify meteorologic conditions, activities such as road traffic Or • Assess ventilation systems
u construction activities during sampling. • Consider evaluating with n
I • Assess the need for dost suppression procedures. • Recommend proper clean-i
• Consider re-sampling after
** As sampled in “Ambient and Indoor Sampling for Public Health Evaluations of Residential Areas Near
WTC.”
‘ National Ambient Air Quality Standard (NAAQS)
2 New York State Ambient Air Quality Standard
’ The range of ratios reported in the 1996 and 2001 draft Ambient Air Criteria Documents for Indoor and
Outdoor concentrations of PM 2,5 could be used to select a multiplier to be applied to the area level of concern.
While estimates (from a limited number of studies) range from slightly less than one, to two (higher if smoking
households are included), 1.5 is proposed as the multiplier, resulting in a value of 60 pg/m’ (It may be necessary
to revisit this value if the ratio for the control homes differs from the historical data, or if EPA has additional
information that would support a different multiplier.). Contribution from a smoker in the home was estimated
in various studies described in the 1996 Criteria Document for PM as contributing 20 to 45 pg/m’ to PM 3 5
time-averaged measurements (12-24 hour samples).
* The concentration of PM at street level monitors can vary greatly from concentrations measured at monitors
sited in accordance with EPA's requirements, The influence of traffic (how much, what types of vehicles), the
presence of bus stops or traffic lights and wind patterns associated with "urban canyons" are all factors that will
influence particle concentrations at street level. Of the limited number of studies identified that looked at
differences between area and street-level monitoring results, street level results were reported to be about 1.3
times higher than area type monitor results for the same time period. From historical data collected in
Manhattan at a rooftop monitor and a street level monitor the ratio for average streetZarea concentrations of
PMjq was about 1.3, and about 1.5 for PM25. Limited data for an additional street-level monitor in NYC
produced similar ratios for each particulate fraction.
^Cooking was estimated to add 10-20 ggZm^ to 12- hour PMio concentrations.
‘ The ACGIH TLV (8 hour TWA) for inhalable particulate matter, not otherwise classified is 10 mg/m\ and is
intended to be protective against worker irritation. A screening value could be developed by applying
uncertainty factors such as a ten-fold uncertainty factor for sensitive sub-populations or for longer than work day
exposures.
Page 39 of 41
CITY_21MC100_003038166
NYC-WTC_000306666
OCR can misread numbers and units. Confirm readings against the page image before using them.