02/22/2002 14:25 FAX 212 9S0 5669 CAPITAL. PROPERTIES igjoog

AKRT, Inc. 111-115 Broadway, New York, New York

of the laboratory results for aldehydes. A complete copy of the laboratory analysis report is included in Appendix B. 2.4 Asbestos Air monitoring for asbestos fibers was performed and samples were analyzed in accordance with USEPA AHERA protocol. Samples were collected by drawing air through a 0.45 pm pore Mixed Cellulose Ester filter utilizing a high volume sampling pump. The sampling pump was calibrated, utilizing a rotometer, with a representative sampler in line prior to and after each sample collection. Samples were analyzed by Transmission Electron Microscopy (TEM). The samples were delivered to, and analyzed by, AlvIA Analytical Services, Inc. (AMA) of Lanham, Maryland. AMA is a certified ELAP, AIHA, and National Voluntary' Laboratory Accreditation Program (NVL.AP) laboratory. Analytical results revealed airborne levels of asbestos fibers below the United State Environmental Protection Agency (USEPA) and New York State Department of Labor (NYSDOL) established clearance criteria for successful completion of an asbestos remediation procedure of 70 asbesto.s structures per square millimeter (s/mm^) All of the asbestos samples were also below the AHERA re-occupancy level of 70 asbestos structures per square millmieter (s/mm^). Table fV contains a summary of the laboratory result.s for asbestos. A complete copy of the laboratory analysis report is included in Appendix B. 2.5 Respirable Particulates and Silica Respirable dust is an airborne material, which is capable of penetrating the respiratory tract into the gas-exchange, non-ciliated region of the lungs. Samples were additionally analyzed for dust, quartz, cristobalite and tridymite concentrations. Cristobalite and tridymite are composed of the same chemistry as quartz., but have a different structure. Respirable particulates were sampled and analyzed in accordance with NIOSH Method 0600 and crystalline silica was analyzed in accordance with NIOSH Method 7500. The sampling method requires air to be drawn through a 5 pm polyvinyl chloride (PVC) pre-weighed filter in a cassette filter holder affixed to an aluminum cyclone, utilizing a personal sampling pump. Ure sampling pump was calibrated, utilizing a rotometer, with a representative sampler in line prior to and after each sample collection. All samples were transported to, and analyzed by. Gal son. All of the crystalline silica and respirable dust samples were determined to be below the OSHA, NIOSH and ACGIH exposure limits. Table V contains a summary of the laboratory results for respirable particulates and silica. A complete copy of the laboratory analysis report is included in Appendix A. 2.6 Volatile Organic Compounds Volatile Organic Compound.s (VOCs) are a group of substances containing carbon and other elements, including hydrogen, oxygen, fluorine, chlorine, bromine, sulfur and nitrogen. VOCs easily vaporize at room temperature and are commonly used in adhesives, solvents, degreasers, cleaning solutions, dry cleaning fluids, components of pesticides and plastics, and ar e among the by-products of combustion. VOCs were sampled and analyzed in accordance with EPA Method TO-15. The sampling method requires the use of evacuated canisters, nie canister uses its own vacuum to dr aw in the air sample, and the airflow is controlled by a regulator. All samples were transported to, and analyzed by, Galson.

Page 3

CITY_DEP_WORBY_CANNATA_SUBP_000007051

NYC-WTC_000306291

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000306291Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000132654 · Box DEP Box 54

A letter from Capital Properties enclosing air quality monitoring reports and cleanup summaries for buildings on Broadway and Trinity Place.

Similar indexed content

Compare copies and versions →