NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 25 pages

Air monitoring report, 111-115 Broadway, Feb 2002

Machine-extracted title · confidence 42%

AKRF air monitoring report prepared for Rosenman & Colin LLP, Feb 21, 2002.

NYC-WTC_000306285–000306309
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

02/22/2002 14:28 FAX 212 980 5669 CAPITAL PROPERTIES ®0I2

AKRF, Inc. ] 11-115 Broadway, New York, New York

3.0 CONCLUSIONS Based on the results of this indoor air quality investigation, AKRF presents die following conclusions; • Levels of polynuclear aromatic hydrocarbons (PAHs), metals, asbestos, respirable particulate, silica, and volatile organic compounds (VOCs) were all observed to be below regulatory and recommended guidelines. • Levels of formaldehyde were observed to be well below OSHA regulatory requirements. Eight samples were observed to be above the NIOSH recommended exposure level. All other levels of aldehydes were observed to be below regulatory and recommended guidelines. . Levels of dioxins above the analytical detection level were identified within one sample All other samples revealed no detectable levels of dioxins. No regulatory limit exists for occupational exposure to dioxins. NIOSH has recommended, absent other guidelines, that levels of dio.xins be reduced to the lowest feasible concentration. . Relative humidity, carbon dioxide and carbon monoxide levels were all observed to be within established ASHRAE guidelmes. Some temperature readings throughout both buildings were observed to be above the ASHRAE guidelines for wintertime conditions. Because the sampling was conducted within unoccupied spaces, temperature variations may be due to the building’s systems settings.

4.0 RECOMMENDATIONS Based upon the conclusions of this indoor air quality investigation, no specific recommendations are presented at this time. However, because of the continuing concerns of people occupying the downtown area along with the continuing press coverage, Rosenman & Colin LLP may wish to consider addiiional indoor air quality monitoring. Should this monitoring be perfonned, AKRF suggests that this monitoring include temperature, relative humidity, carbon dioxide, carbon monoxide, respirable dust and asbestos sampling. In addition, mercury should be sampled for in both the dust and fume forms. To alleviate any possible concerns with formaldehyde, sampling in the affected spaces could be conducted with the ventilation system in operation, as it would be with full occupancy. Sampling could also be conducted on occupied floors, representative of the building’s spaces. Similarly, additional dioxin sampling could be conducted to provide additional data m relation to the single air sample that revealed detectable levels of dioxins.

Page 6

CITY_DEP_WORBY_CANNATA_SUBP_000007054

NYC-WTC_000306294

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000306294Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000132654 · Box DEP Box 54

A letter from Capital Properties enclosing air quality monitoring reports and cleanup summaries for buildings on Broadway and Trinity Place.

Similar indexed content

Compare copies and versions →