NYC 9/11 Public Portal Document
H. A. Bader^ Consultants
TLI Project; 56392 Method 8290 PCDD/PCDF Analysis (b)
Jlient Sample: 611 Analysis File: W010209
Internal Standards Amt. (ng) % Recovery QC Limits Ratio RT Flags
”C,r2.3.7,8-TCDF 3.2 80.7 40%-130% 0.75 25:54
'’C,2-2,3.7,8-TCDD 3.2 79.8 40%-130% 0.78 26:37
'’C,j-l,2.3,7.8-PeCDF 3.5 86.8 40%-130% 1.51 29:51
'’Cij-1,2,3,7,8-PcCDD 3.5 86.4 40%-130% 1.52 30:53
'’C,2-1,2,3.6,7.8-HxCDF 3.5 88.4 40%-130% 0.51 33:25
'’C,2-1,2.3,6,7,8-HxCDD 3.5 88.6 40%-130% 1.21 34:05
'’C.:-1.2,3,4,6,7.8-HpCDF 2.9 73.7 25%-130% 0.45 36:17
'’C.2-!,2,3,4,6,7,8-HpCDD 3.3 81.4 25%-I30% 1.01 37:19
'’C,2-1,2.3,4,6.7,8,9-OCDD 5.2 65.2 25%-I30% 0.86 40:54
Surrogate Standards (Type B) Amt. (ng) % Recovery QC Limits Ratio RT Flags
'’Ci2-2,3.4,7,8-PeCDF 3.8 94.1 40%-130% 1.48 30:33
'’C,!-1.2,3,4,7,8-HxCDF 3.5 88.5 40%-130% 0.50 33:19
'’C,2-1.2,3,4,7.8-HxCDD 3.2 81.2 40%-130% 1.20 34:00
‘’C„-l,2.3,4,7,8,9-HpCDF 3.0 74.0 25%-130% 0.43 37:49
Other Standard Amt. (ng) % Recovery QC Limits RT Flags
”Cl4-2,3,7,8-TCDD 0.34 84.6 40%-130% 26:38
Alternate Standards (Type B) Amt. (ng) % Recovery QC Limits Ratio RT Flags
«C,rl,23.7.8,9-HxCDF 3.2 79.7 40%. 130% 0.50 34:3^
'»C.r2.3.4.6.7.8-HxCDF 3.5 86.3 40%-130% 0.50 33:54
Recovery Standards Ratio RT Flags
''C.2-1,2,3,4-TCDD 0.81 26:27
'>C,3-1,2,3,7,8,9-HxCDD 1.19 34:24
Data Reviewer: 01/17/2002
Page 2 of 2 Mm.PSR »l 00, LARS e 25 Ulm
Triangle Laboratories, Inc.®
801 Capitola Drive • Durham, North Carolina 27713 Printed; 14:44 01/17^(^^
Phone; (919) 544-57'29 • Fax: (919) 544-5491
CITY_21MC100_003114123
NYC-WTC_000304867