NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 28 pages

GC/MS peak listing for W010206B, Jan 2002

Machine-extracted title · confidence 39%

Listing of GC peaks, relative retention times, and TCDF/TCDF-related data.

NYC-WTC_000304793–000304820
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Page No. 5 Listing of w010206B.dbC 01/17/2002 Matched GC Peaks / Ratio / Ret. Time

Compound/ DC.Log Omit Why ..RT. OK Ratio Total.Area/Ht Area/Hc.Peakl Area/Ht.Peak! Rei.RT Compound.Name . . ID.. Flags.

390-392 7 Peaks 53,375.87

13C12-HXCDD 1.05-1 .43 0.971-1.029 402-404 DC NL Height 11-90 8.01 3 . 09 DC WL 33:02 RO> 2.94 4,23 0.969 DC WL 33:03 ROJ 1.69 12 . 30 0.970 DC SN 3 3.-06 1.14 12,16 0.971 33:29 ROI 3.43 77.75 119.03 34.71 0.982 DC SN 33:35 ROI 3.82 10.95 0.905 34:00 1.24 9,002.07 4.975.97 4.026.10 0.998 13C12-HXCDD 478 SUR3 34:05 1.19 10,330.44 5,622.56 4,707.80 1.000 13C12-HXCDD 678 IS5 Height 3,329.36 1,811.53 1,517.83 34:24 1.27 11,356.01 6,356.31 5,000.00 1.009 13C12-HXCDD 709 RS2 34:36 1.14 55.91 29.01 26.10 1.015 DC SN' 34:43 ROI 0.41 19.71 1.019 402-404 5 Peaks 30,022.98

Above: HxCDD / KpCDF Follows

HpCDF 0.88-1.20 0.890-1.110 408-410 DC NL Height 26.92 23.18 3.74 36:18 1.08 5,582,77 2,895.27 2,687.50 1.000 1234679-HpCDF AN X X 36:34 RO 1.07 1,608.43 832.55 775.88 1.008 36:42 1.07 1,185.42 613.84 571.58 1.011 DC SNJ 37:20 RO 2.79 39.13 1.029 37:49 1.06 587.75 302.79 264.96 1.042 1234789-HpCDF AN DC WHt 30:26 RO 1.57 490.33 1.059 400-410 4 Peaks 8.964.37

13C12-HpCDF 0.37-0.51 0.945-1.110 418-420 DC NL Height 10.54 6.41 4.13 36:17 0.43 7,458.55 2,243.45 5,215.10 1.000 13C12-HPCDF 678 IS6 Height 2,118.39 '638.42 1.479.97 DC SN 36:56 RO> 0.63 30.99 1.018 37:49 0.44 5,382.48 1,650.50 3,731.98 1.042 13C12-HpCDF 789 SUR4 418-420 2 Peaks 12,841.03

Above: HpCDF / HpCDD Follows

HpCDD 0.88-1.20 0.893-1,107 424-426 DC NL Height 9.01 3.01 5.20 DC SN7 36:25 RO 0.21 12.42 0.976 36:35 0.96 5,790.39 2.633.42 2.956.97 0.980 D d nhI 36:54 RO 0.24 4 9.67 0.969 37:20 0.98 4.313.85 2,138.51 2.175.34 1.000 1234678-HpCDD AN DC WHt 37:37 RO 1.46 19.28 1.008 424-426 2 Peaks 10,104.24

13C12-HpCDO 0.08-1,20 0.973-1.027 436-438 DC NL Height 10.12 7.17 2.95 37:19 1.05 6,869.12 3,524,72 3,344.40 1.000 13C12-HpCDD 676 IS? Height 1,789.62 911-23 078.39

Triangle Laboratories, Inc.® 801 Capitola Drive • Durham, North Carolina 27713 Printed: 14:16 01/17/2002 Phone; (919) 544-5729 • Fax: (919) 544-5491 235

CITY_21MC100_003114003

NYC-WTC_000304797

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000304797Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →