CA Environmental, Safety, and Health WTC Daily Site Evaluation* 10(23/01

Major Issues Location Disposition Status Gas cylinders improperly secured. AMEX building Discussed with AMEC safety rep. NEW

I Inconsistent use of proper PPE (e.g., safety glasses, respiratory protection) Lack of fall protection. WTC 1 AMEX building Discussed with AMEC safety rep. Discussed with AMEC safety rep. NEW COMP The crane was backed off the pads, DDC & structural engineers are Crack observed in slurry wall. WTC6 OPEN inspecting the area to determine the stability of the wall.

Tl >■ Inadequate fall protection. Inadequate dust suppression. Inconsistent use of proper PPE (e.g., hearing protections, safety glasses, respiratory 90 West WTC 2 Discussed with Bovis safety rep. & Atlantic Heygt safety rep. Bovis Safety is working with FDNY to correct. NEW OPEN

S' protection). WTC2 Met with Bovis safety rep. to discuss corrective action plan. OPEN

J Inadequate barricading. WTC 2 South side Discussed with Bovis safety rep. ' OPEN

Discussed with Tully safety rep., NYPD (Capt. Motte), and Customs agent Discovery of ammunition on pile. Southeast comer of WTC 6 (Victoria Ovis). Tully will not cut in that area but will use grappler as NEW directed by NYPD & Customs (Ordinance experts). Southeast comer of WTC 6 Tully safety rep. was informed, and incident report will be submitted to Employee injury. NEW s- Bechtel safety. Inadequate vehicle spotting. WTC2&4 Discussed with Tully safety rep. NEW Truck made sharp turn and hit Tully gator that had FDNY siting in it. Liberty Tully safety rep informed and incident report requested by Bechtlel Safety. OPEN Tully ordered flash arrestors and will place them on torch once they come Lack of flash arrestors on cutting torches. Various locations OPEN in. Gas cylinders improperly stored. Various locations Contractor’s safety rep. was informed. OPEN Inconsistent use of proper PPE (e.g., safety glasses, respirators). All areas Discussed with contractor’s safety personnel. OPEN Inadequate dust suppression. Tully Discussed with Tully safety rep. OPEN

WTC 7 (stacked Conex Inadequate fall protection. Discussed with Seasons safety rep. OPEN boxes) Backup alarm not loud enough on CAT front end loader 960F. WTC 7 Discussed with Seasons safety rep._________________________ OPEN Inadequate barriers by tube trailer. WTC 7 Turner Safety rep is working w/FDNY to correct. OPEN No backup alarm on Seasons dump truck #38. (NJAF179H) WTC 7 Discussed with Seasons safety rep. OPEN Various locations Turner ordered flash arrestors and installed. 1 burner removed flash Lack of flash arrestors on cutting torches. OPEN arrestor. Discussed with Turner safety rep. Diesel fuel tanks not grounded or posted. Barclay St. Electrical cords were discovered to be cut. OPEN Gas cylinders improperly secured and stored. WTC 7 Met with Seasons safety rep. to discuss corrective action plan. OPEN Inconsistent use of proper PPE, particularly respiratory protection on pile. WTC 7 Met with Seasons safety rep. to discuss corrective action plan. OPEN O Dust suppression. WTC 7 Excellent job of watering and keeping dust down. OPEN H K I to

S o o o I o o cr^ co to to ■•Site assessments are conducted daily in the WTC disaster area. The primary focus is to identify and correct any major unsafe practices and unsafe conditions. co os

NYC-WTC_000304473

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000304473Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

WTC Daily Site Evaluation, Oct 23, 2001 · Box unavailable

NYC-WTC_000204854

Daily environmental, safety, and health evaluation log for the World Trade Center site dated October 23, 2001, noting PPE usage, fall protection, and structural cracks.

12 shared non-person entities · 1 shared topics · similarity 0.985

machine-extracted · confidence unavailable · Check page ↗

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

WTC Daily Site Evaluation, Oct 23, 2001 · page 1

NYC-WTC_000204854

Daily environmental, safety, and health evaluation log for the World Trade Center site dated October 23, 2001, noting PPE usage, fall protection, and structural cracks.

Similarity score 0.988 (not a probability)

machine-extracted · confidence unavailable · Check page ↗

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000302570

WTC site safety observations and PPE/fall protection notes.

Similar indexed content

NYC-WTC_000266576

Daily site evaluation notes noting safety issues and PPE concerns.

Similar indexed content

NYC-WTC_000204854

Daily environmental, safety, and health evaluation log for the World Trade Center site dated October 23, 2001, noting PPE usage, fall protection, and structural cracks.

Similar indexed content

NYC-WTC_000407564

Daily site safety evaluation noting PPE, elevated hazards, and structural concerns at WTC sites; safety recommendations.

Similar indexed content

NYC-WTC_000187868

Daily environmental safety evaluation report for the WTC site noting PPE issues, fall protection gaps, and structural cracks.

Similar indexed content

Compare copies and versions →