NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 36 pages

Draft: environmental monitoring plan for WTC debris

Machine-extracted title · confidence 50%

Draft plan for environmental monitoring of exposure to fibers after WTC collapse.

NYC-WTC_000302886–000302921
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

(um) (um) (C)

a aspect ratio <5:1 L-a 0-a C-a

b <0.5 L-b 0-b C-b

c >0.5 L-c 0-c C-c

d <0.5 L-d 0-d C-d

e <0.5 5-10 L-e 0-e C-e

f. <0.5 > 10 L-f 0-f C-f

The results for bins L-d, L-e, and L-f must not be statistically different from each other at the 90% confidence interval, tested using the statistical procedure documented in Appendix F. No formal test will be performed for other bins, but it is expected that there should be no more than about 5% of all bins that differ at the 95% confidence level using the statistical comparison approach in Appendix F.

Validation of QC Samples for PCM

All QA samples for PCM analysis (both re-analysis and re-preparation) must conform with the acceptance criteria specified in NIOSH Method 7400. In brief, the coefficient of variation between the original and the re-preparation sample must not be greater than 0.45. If the laboratory has established values more stringent than this (as described in NIOSH 7400), these more stringent standards will apply.

Validation of Field Data

Data validation for field samples will be performed by ensuring that each sample is accompanied by a complete chain of custody record, a complete field data sheet, and a properly completed and signed laboratory data sheet. Any sample that lacks one or more of the required sets of documentation will be excluded unless the missing sample identification and documentation can reliably be obtained. In addition, the field log book and the analytical report for each sample will be reviewed to determine if there are any notations which indicate that the sample may not be reliable. Any sample with a notation which indicates that the result may not be reliable will be considered unreliable unless a subsequent review determines that the datum is reliable. Data points determined to be unreliable or invalid will be permanently flagged with an “R” qualifier in the original raw data set and excluded from subsequent data analyses, summaries, and reports.

D3. RECONCILIATION with DQOs

The data reports will be reviewed by the Program Director for the City of New York, and appropriate State and Federal officials to assess data quality in accordance with DURA (1992), and to determine whether the data are adequate to meet the project objectives. In particular, the project team will review any results which fall outside the DQOs and decide (per DURA 1992

CITY_21MC100_009029056

NYC-WTC_000302917

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000302917Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →