NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

TEM report, Stuyvesant HS 5784, Oct 2001

Machine-extracted title · confidence 55%

TEM analysis results for Stuyvesant HS air sample 5784 (exterior/interior) with AHERA method.

NYC-WTC_000302845
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/28/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction ISAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; AllERA Final Ru2.e, FPJk Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 3C, 1987

Sample Identification Analysis Parameters

Pro j ect/Site: New Stuweisant H.S, 345 Chambers St., NY, NY TEM Sample No.: 5784 62387 Exterior & Interior of Building & Roof Date Received: 10/27/01 Grid Openings Analyzed:__ 4

Project Sample No.: 2 Average Grid Opening: 106.00 um

Air Volumt;: 1528 liters Total Area Analyzed: C.04 50 mm2

Filter Type MCE 25 mm dian ., Pore Size: 0.45 um Analytical Sensitivity: s /mm2 Effective Aree; 385 mm2 0.0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc nqm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 c

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes amoiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0 . 0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimsted uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Aneilyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003112655

NYC-WTC_000302845

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000302845Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293856

Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.

Similar indexed content

Compare copies and versions →