NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

ASTM/D5755-95 method overview, NYC asbestos lab

Machine-extracted title · confidence 29%

Analytical standard description page for dust analysis by microscopy and TEM.

NYC-WTC_000302625–000302627
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

A. BULK SAMPLES

Definition: Any material containing more than 1% asbestos as determined by PLM (Polarized Light Microscopy). Methodology - Appendix A Subpart F 40 CFR part 763 section 1

B. AIR SAMPLES

PCM (Phase Contrast Micioscopy) Clearance Criteria - O.Olfibers/cc or less Limitation PCM caimot distinguish asbestos from non-asbestos fibers PCM does not count fibers sizes less than 5 micron in length Methodology - NIOSH 7400

TEM (Transmission Electron Microscopy) Clearance Criteria - 70 structures / sq.mm TEM can count fiber sizes less than 0.5 micron and can differentiate between asbestos and non-asbestos fibers Methodology - AHERA AHERA- (Asbestos Hazard Emergency Response Act) standard is a very stringent indoor standard that is used to determine whether children may re-enter a school building after asbestos has been removed. EPA and City used this standard because it is most stringent and protective, even though it is unlikely that the public will be exposed to asbestos from WTC site for extended period of time.

C. DUST SAMPLES

EPA or NYS or NYC does not have a standard for sampling dust. The presence of asbestos in dust is not necessarily a significant hazard. The dust must become airborne and be inhaled for it to cause health problems. Measurement of asbestos in air are more accurate indicators of the potential for exposure.

Methodology - American Sc :iety for Testing and Materials - ASTM D5755 Limitation (As per ASTM document attached) 5.1.1 This test method does not describe procedures or techniques required to evaluate the safety or habitability of buildings with ACM or compliance with federal or state or local regularions or statutes. 5.1.2 At present, a single relationship between asbestos containing dust and potential human exposure does not exist.

CITY_21MC100_010234794

NYC-WTC_000302627

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000302627Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →