11/01/2001 18:41 21233372375 OSHA REGION 2 PAGE 03/03

Ionizing Radiation: A survey of the rubble pile was conducted on 10/22-10/23 to chedt for latent radiation with particular attention to alpha radiation. Preliminary results show no elevated levels... Dioxins; The single sample taken by OSHA and analyzed by the EPA, representing exposure on the pile, showed elevated levels of dioxins. These levels were substantially hiwer than background levels but comparable-to levels found by the EPA on the rubble pile. The dioxins found here are emitted from the on-going : rubble fire. OSHA does not have a worker standard for dioxins. Dioxins are considered collectively as suspect human carcinogens. Some of the individual compounds are considered to be known human carcinogens. OSHA has taken seven additional samples which have been forwarded for analysis. OSHA is currently conducting additional sampling for dioxins and is coordinating with EPA, and Salt Lake City Analytical Laboratory to more fully characterize exposure and risk around the rubble pile. Polynucleated Aromatic . Hydrocarbons; . OSHA identified several elevated samples, three of which reached or exceeded OSHA’s coal tar pitch volatiles PEL of These personal samples were taken on tlie pile on iron workers and grappler operators. OSHA continues to strongly recommend the use of respiratory protection when working on the rubble pile. Fretjn R-22: In response, to information about exposure to the combustion by-products of Freon 22 used in the air conditioning systems of WTC towers, OSHA conducted sampling for fluorides.as HF. Results revealed non-detectable levels. '

Page 2 of 2

CITY_21MC1OO_OO24782O7

NYC-WTC_000302136

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000302136Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000181790

Summary of OSHA air monitoring results for asbestos in the Financial District and rubble pile from September to October 2001.

Similar indexed content

Compare copies and versions →