NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 5 pages

Bulk Sample Analysis Report, NYC-DCAS 4M1 [name]

Machine-extracted title · confidence 58%

Bulk sample analysis for DCAS project at 4M1 [name] building.

NYC-WTC_000301830–000301834
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

DCAS Fax:212-669-8840 Oct 11 2001 11:04 P. 13 MMtiunswuiwie

low Waad city 1# NwMW J li *1 L lei; ns-w Fax; 7S.18B

SULK SAMPLE ANALYSIS REPORT CLIENT; NYC-DCAS BUILDING ADDRESS: 49-51 Chamber Street PHOJECT#; Client Sample ID#: 16 17 18 19 20 Lab Sampis ID#: 0l0918C’W9 01091 SC-1000 O10918C-I0O’ 010918C-1002 010918C-I003 Sample Location; Staircase "E' Elevator Lobby Elevator Lobby Staircase E File Cabinet by East East East East Elevator #5 oTh Floor Sth Floor 3rd Floor 3rd Floor 3rd Floor

Homogfitelry: Yes Yc£ Yes Yes Yes Sample DescripEiort; Floor Floor Floor Floor Cabinet File Wipe Wipe Wipe Wipe Wipe

Coicr: Elk Bik Bik 81k Blk Texture: Mi^ed Mixed Ntixed Mixed Mixed Sample Treatment: None None None None - None

Asbestos .Present; (Type & Percent) ND ND ND ND ND Total Percent Asbestos; 0% 0% 0% OY. O’/a Other Fibr. Mat, (Type & Percent); 15%CELL 3%CELL 5%C£LL 4%CELL 7%CELL 3%SYNTH 10%SYNTH 5%SYNTH Non Fibr. .Mat, (Percent): 85% 92% 85% 96% 88% Date Received: 9/18/01 Date of Analysis: 9/18/01 Date of Repon: 9/18/01

Analyst; Lab Man: (er; L Roody Low David * * Analysis of samples is perforated bv Poldi'ized Light Microscopy (PLM) - Point Counting Method (EPA600/M4-S2-02C) * Analytical eauipraents: Stereobiftdcular microscope (MEIJI EMT-Seria! # 25930). Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * FLM is not consistently reliable in detectins asbestos in floor coverings and similar non-friable organically bound materials. Ouanfitative transmission electron microscopy is currently the only method that can be used to determine If this materiaS can be considered or treated as tion-asbtsios-fiontainins * Samples Mil be stored for nineiv (90) days and then returned to the client upon recuest * The results relate only to the items calibrated or tested. * The certificate of repon shall not be reproduced without the written approval of the laooratory. * The report must not be used by the client to claim endorsement bv WL-^P or any agency of ths US Government. NYS^DOfi ELAP #11273 A7Yr-.-VH.-tP# 102047 A/HA#: 100269

4

CITY_21MC100_011222445

NYC-WTC_000301833

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000301833Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000301827

Bulk sample analysis report for NYC-DCAS building at Health Department location.

Similar indexed content

Compare copies and versions →