NYC 9/11 Public Portal Document
Polynuclear Aromatic Hydrocarbons:
A total of 12 air samples were collected for polynuclear aromatic hydrocarbons (PAHs)
including anthracene, benzo(a)anthracene, benzo(b)fluoranthene, benz6(a)pyrene, chrysene,
phenanthrene, and pyrene. Only trace amounts of PAHs were detected on any the air samples.
Four of the PAHs detected on the air samples in trace amounts are the suspected human
carcinogens benzo(a)anthracene, benzo(b)fluoranthene, benzo(a)pyrene, and chrysene.
Respirable Particulate:
A total of 18 air samples were collected for respirable particulate and indicated TWA
concentrations ranging from none detected to 0.32 mg/m^. These measurements are well below
the OSHA PEL of 5 mg/m^. (NIOSH does not currently have an REL for respirable particulate.)
Respirable Cirystalline Silica:
A total of 18 air samples were collected for respirable crystalline silica. No respirable crystalline
silica was detected on any of these air samples.
Total Particulate:
A total of 36 air samples were collected for total particulate and indicated TWA concentrations
ranging from none detected to 2.3 mg/m\ These measurements are well below the OSHA PEL
for total particulate of 15 mg/m^. (NIOSH does not currently have an REL for total particulate.)
Volatile Organic Hydrocarbons:
A total of 76 air samples were collected for volatile organic hydrocarbons including benzene,
ethyl benzene, styrene, toluene, and xylene(s). Except for benzene, only trace amounts of VOCs
were detected on any of these air samples. Two of these samples (0.35 and 0.46 mg/m^)
exceeded the NIOSH REL for benzene of 0.32 mg/m^ but did not exceed the OSHA PEL for
benzene of 3.2 mg/m^.
4
CITY_21MC100_003097147
NYC-WTC_000301219
OCR can misread numbers and units. Confirm readings against the page image before using them.