asbestos and non-asbestos fibers. No asbestos fibers were detected in over 45% (56) of these air
samples. The remaining 63 air samples indicated TWA concentrations ranging up to 0.063
asbestos fibers/cc as determined by TEM, none of which exceeded the NIOSH REL and the
OSHA PEL of 0,10 fibers/cc. These TEM results indicate that the vast majority of the fibers
reported fi-om the PCM analyses are non-asbestos fibers. Further analyses are being performed
to determine the nature of these non-asbestos fibers.
CarboEB Mom oxide:
A total of 98 air samples were collected for carbon monoxide indicating TWA concentrations
ranging from 0.16 to 242 ppm. All but 4 of these measurements were below the NIOSH REL of
35 ppm and all but 1 were below the OSHA PEL of 50 ppm. One sample (242 ppm) exceeded
the NIOSH recommended ceiling limit of 200 ppm. Additionally, 2 instantaneous peak
measurements (1,239 and 1,368 ppm) exceeded the NIOSH immediately dangerous to life or
health (IDLH) value of 1,200 ppm and 15 others exceeded the NIOSH recommended ceiling
limit of200 ppm. All carbon monoxide measurements exceeding one or more of these
evaluation criteria were being performed by workers using either a cutting torch or a cutting saw.
This underscores the need for adequate ventilation and worker awareness when using these tools.
Diesel Exhaust:
A total of 8 air samples were collected for diesel exhaust indicating TWA (elemental carbon)
concentrations from none detected to 0.023 mg/m’. These measurements are all well below the
proposed American Conference of Governmental Industrial Hygienists (ACGIH®) threshold
limit value (TLV®) for diesel exhaust of 0.20 mg/m^ (elemental carbon). (NIOSH and OSHA
currently have no evaluation criteria for diesel exhaust.)
Freon® 22;
A total of 5 air samples were collected for Freon® 22 (chlorodifluoromethane). No Freon® 22
was detected on any of these air samples.
Hydrogem Sulfide;
A total of 10 air samples were collected for hydrogen sulfide. Hydrogen sulfide was detected on
only 1 of these samples indicating a TWA concentration of 1.0 ppm and a instantaneous peak
concentration of 3.0 ppm. These measurements are well below the NIOSH recommended ceiling
limit and the OSHA ceiling limit of 10 ppm.
Imorgamic Acids;
A total of 27 air samples were collected for inorganic acids including hydrobromic, hydrochloric,
hydrofluoric, nitric, phosphoric, and sulfuric acids. Except for sulfuric acid, only trace amounts
2