NYC-WTC_000300246
TEM asbestos analysis results; AHERA method used for Stuyvesant HS samples.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Asbestos fiber TEM analysis data for exterior/interior areas of the building, Apr 2002.
NYC-WTC_000300024–000300026OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Attn: Mr. Bernard Orlan Received: 4/19/02 7:30:00 PM N. Y.C. Board of Education ATC Group#: 7467 28-11 Queens Plaza North Analysis Date: 4/20/02 Long Island City, NY 11101 Fax: (212)475-4122 Phone: (212)477-8941 Project: New Stuyvesant H. S., 345 Chambers St., NY , NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Area Non Asbestos # Structures Sensitivity Concentration Sample l^olume Analyzed Asb Typefs) 0.5fi-S 5fi (S/cc) (S/mm^) (S/cc) Notes
8 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 < 0.0044 7467 -S
9 1944.00 0.0450 0 None Detected 0 0 0.0044 < 22.24 < 0.0044 746 7 -9
10 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 < 0.0044 7467 -10
II 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 < 0.0044 7467 -1/
12 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7467 -12
13 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 < 0.0044 7467 -13
14 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 < 0.0045 7467 -!4
15 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 < 0.0045 7467 -15
16 1952.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7467 -16
MICHAEL A. GORYCKl, Ph.D. MARK PEYSAKHOV
Analyzed by: .pproved by:
Disclaimer The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collated by non-laboratory personnel. This lab is only responsible for data reported in structures/mm’ This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government This reports relates only to the samples reported above. Quality control data (including 95% confidence limits and laboratory and analysis' accuracy and precision) is available upon request
Accredited for NVLAP PLIvVrEM #101187-0, NY State ELAP #10879
Page 2 of 3
CITY_21MC100_0 03095562
NYC-WTC_000300025
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000300246
TEM asbestos analysis results; AHERA method used for Stuyvesant HS samples.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299938
TEM asbestos analysis results for site, 04/09/02.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000185047
Formal laboratory report detailing transmission electron microscopy results for asbestos fiber analysis conducted on behalf of the New York City Board of Education.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299891
TEM asbestos analysis report for New Stuyvesant HS, exterior/interior areas, 04/02.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298708
Asbestos fiber TEM results for air samples at the school, AHERA methodology.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299177
TEM asbestos analysis results for New Stuyvesant High School, Apr 2002.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000184909
Formal laboratory report detailing TEM asbestos fiber analysis for a high school project dated June 18, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299032
TEM asbestos analysis results for New Stuyvesant High School exterior/interior samples, Apr 12, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298981
TEM asbestos analysis results for New Stuyvesant High School, Apr 2002.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299007
TEM asbestos analysis results for New Stuyvesant High School exterior/interior air samples, Apr 2002.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300328
TEM asbestos analysis report for exterior/interior of New Stuyvesant High School, May 27, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299929
TEM asbestos analysis results for exterior/interior areas, 04/08/02.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000300236
TEM asbestos analysis results for Stuyvesant High exterior/interior samples.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298401
TEM asbestos analysis results for air samples at New Stuyvesant High School, May 5, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300201
TEM asbestos analysis results for exterior/interior areas under AHERA.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299233
TEM asbestos analysis results for exterior/interior areas, New Stuyvesant High School.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298301
TEM analysis of air samples for asbestos at New Stuyvesant High School, AHERA.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000185047
Formal laboratory report detailing transmission electron microscopy results for asbestos fiber analysis conducted on behalf of the New York City Board of Education.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM asbestos analysis results; AHERA method used for Stuyvesant HS samples.
Similar indexed content
TEM asbestos analysis results for site, 04/09/02.
Similar indexed content
NYC-WTC_000185047
Formal laboratory report detailing transmission electron microscopy results for asbestos fiber analysis conducted on behalf of the New York City Board of Education.
Similar indexed content
TEM asbestos analysis report for New Stuyvesant HS, exterior/interior areas, 04/02.
Similar indexed content
Asbestos fiber TEM results for air samples at the school, AHERA methodology.
Similar indexed content