Attn: Mr. Bernard Orlan Received: 4/14/02 6:00:00 PM N.Y.C. Board of Education ATC Group#: 7811 28-11 Queens Plaza North Analysis Date: 4/14/02 Long Island City, NY 11101 Fax: (212)475-4122 Phone: (212)477-8941

Project: New Stuyvesant H. S., 345 Chambers St., NY , NY

Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Area Non Asbestos # Structures Sensitivity Concentration Sample Volume Analyzed Asb Type(s) O.Sft-S 5ft (S/cc) (S/mm^) (S/cc) Notes

17 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 < 0.0045 7811 -17

*8 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7811 -IS

19 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7SII -19

20 1928.00 0.0450 0 None Delected 0 0 0.0044 <22.24 <0.0044 7811 -20

2' 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 < 0.0044 7811 -21

MARK PEYSAKHOV MICHAEL A. GORYCKI, Ph.D.

Analyzed by: pproved by:

Disclaimer The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This HD is only responsible for data reported in structures/mmT This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government This reports relates only to the samples reported above. Quality control data (including 95% confidence limits and laboratory and analysis’ accuracy and precision) Is available upon request

Accredited for NVLAP PLM/TEM #101187-0, NY State ELAP #10879

Page 3 of 3

CITY_21MC100_0 03095420

NYC-WTC_000299983

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000299983Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000300220

TEM asbestos analysis report for New Stuyvesant High School exterior/interior areas.

Similar indexed content

NYC-WTC_000299891

TEM asbestos analysis report for New Stuyvesant HS, exterior/interior areas, 04/02.

Similar indexed content

NYC-WTC_000300024

Asbestos fiber TEM analysis data for exterior/interior areas of the building, Apr 2002.

Similar indexed content

NYC-WTC_000299938

TEM asbestos analysis results for site, 04/09/02.

Similar indexed content

NYC-WTC_000300246

TEM asbestos analysis results; AHERA method used for Stuyvesant HS samples.

Similar indexed content

Compare copies and versions →