NYC-WTC_000299891
TEM asbestos analysis report for New Stuyvesant HS, exterior/interior areas, 04/02.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗TEM asbestos analysis results for abatement sites, 04/10/02.
NYC-WTC_000299944–000299946OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Attn: Mr. Bernard Orlan Received: 4/10/02 9:00:00 PM N.Y.C. Board of Education ATC Group#: 7373 28-11 Queens Plaza North Analysis Date: 4/10/02 Long Island City, NY 11101
Fax: (212) 475-4122 Phone: (212)477-8941
Project: New Stuyvesant H. S., 345 Chambers St., NY , NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Area Non Asbestos # Structures Sensitivity Concentration Sample Volume Analyzed Asb Type(s) O-Sfi-S 5fi (S/cc) (S/mm^) (S/cc) Notes
8 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7373 -8
9 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7373 -9
10 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7575 -10
11 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7373 -II
12 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7575 -12
13 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7575 -13
14 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7575 -14
15 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 7575 -15
16 1960.00 0.0450. 0 None Detected 0 0 0.0044 <22.24 <0.0044 7373 -16
MICHAEL A. GORYCKI, Ph.D. MARK PEYSAKHOV Analyzed by: Approved by
Disclaimer: The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This labis only responsible for data reported in structures/mmT This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. This reports relates only to the samples reported above. Quality control data (including 95% confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
Accredifed for NVLAP PLMAEM #101187-0, NY State ELAP #10879
Page 2 of 3
CITY_21MC100_003095303
NYC-WTC_000299945
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000299891
TEM asbestos analysis report for New Stuyvesant HS, exterior/interior areas, 04/02.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300246
TEM asbestos analysis results; AHERA method used for Stuyvesant HS samples.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299938
TEM asbestos analysis results for site, 04/09/02.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000194112
Formal laboratory report from ATC Associates detailing transmission electron microscopy results for asbestos fibers in air samples collected from a New York City Board of…
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000184909
Formal laboratory report detailing TEM asbestos fiber analysis for a high school project dated June 18, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000185047
Formal laboratory report detailing transmission electron microscopy results for asbestos fiber analysis conducted on behalf of the New York City Board of Education.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300024
Asbestos fiber TEM analysis data for exterior/interior areas of the building, Apr 2002.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299906
Asbestos TEM analysis results for building site, 04/04/02.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298301
TEM analysis of air samples for asbestos at New Stuyvesant High School, AHERA.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298751
TEM analysis results for air samples at New Stuyvesant High School, exterior/interior, received Jun 11, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299032
TEM asbestos analysis results for New Stuyvesant High School exterior/interior samples, Apr 12, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273471
TEM asbestos analysis results for air samples at New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000299891
TEM asbestos analysis report for New Stuyvesant HS, exterior/interior areas, 04/02.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299213
TEM asbestos analysis results for exterior/interior areas of New Stuyvesant High School.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299938
TEM asbestos analysis results for site, 04/09/02.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298301
TEM analysis of air samples for asbestos at New Stuyvesant High School, AHERA.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298696
Asbestos fiber TEM analysis results for New Stuyvesant High School air samples, AHERA methodology.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000194112
Formal laboratory report from ATC Associates detailing transmission electron microscopy results for asbestos fibers in air samples collected from a New York City Board of…
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM asbestos analysis report for New Stuyvesant HS, exterior/interior areas, 04/02.
Similar indexed content
TEM asbestos analysis results; AHERA method used for Stuyvesant HS samples.
Similar indexed content
TEM asbestos analysis results for site, 04/09/02.
Similar indexed content
NYC-WTC_000194112
Formal laboratory report from ATC Associates detailing transmission electron microscopy results for asbestos fibers in air samples collected from a New York City Board of…
Similar indexed content
NYC-WTC_000184909
Formal laboratory report detailing TEM asbestos fiber analysis for a high school project dated June 18, 2002.
Similar indexed content