NYC 9/11 Public Portal Document
Attn: Mr. Bernard Orlar Received: 6/16/02 5:00:00 PM
N.Y.C. Board of Education ATC Group#: 8137
28-11 Queens Plaza North Analysis Date: 6/17/02
Long Island City, NY 11101
Fax: (212)475-4122 Phone: (212)477-8941
Project: H.S. for Leadership & Public Service
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
Area Non Asbestos # Structures Sensitivity Concentration
Sample l^oliime Analyzed Asb Type(s) 0.5fi-5 5/7 (S/cc) (S/mm^) (S/cc) Notes
20 1806.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047
SI37 -17
21 1816.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047
SI37 -IS
MARK PEYSAKHOV MICHAEL A. GORYCKl, Ph.D.
Analyzed by: (proved by:
Disclaimer: The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This laB-is-enty responsiole
for data reported in structures/mmT This report may not be reproduced, except in full, without written approval by ATC Associates Inc This report may not be used to claim
product endorsement by NVLAP or any other agency of the U.S, Government. This reports relates only to the samples reported above. Quality control data (including 95%
confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
Accredited for MVLAP PLIdCEM #101187-0, NY State ELAP #10879
Page 5 of 3
CITY_21MC1OO_OO3O94437
NYC-WTC_000299773
OCR can misread numbers and units. Confirm readings against the page image before using them.