NYC 9/11 Public Portal Document
Attn: Mr, Bernard Orlan Received: 6/25/02 7:00:00 PM
N.Y.C. Board of Education ATC Group#: 8276
28-11 Queens Plaza North Analysis Date: 6/25/02
Long Island City, NY 11101
Fax: (212) 475-4122 Phone; (212) 477-8941
Project; New Stuyvesant H. S. , 345 Chambers St., NY , NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
Area Non Asbestos # Structures Sensitivity Concentration
Sample Coluine Analyzed Asb Type(s) 0.5fl.5 5fl (S/cc) (S/mm^) (S/cc) Notes
17 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
S276 -J7
18 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045
8276 -78
19 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045
527d -J9
20 1920.00 0.0450 0 None Detected 0 0 0.0045 <22,24 <0.0045
S276 -20
21 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045
S276 -2!
MARK PEYSAKHOV MICHAEL A. OORYCKl, Ph.D.
Analyzed by: IVed by:
Disclaimer: The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. ThiTIab is only responsible
for data reported in structures/mmT This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may no: be used to claim
product endorsement by NVLAP or any other agency of the U.S. Government. This reports relates only to the samples reported above. Quality control data (including 95%
confidence limits and iafcoratory and analysis' accuracy and precision) is available upon request.
Accredited for NVLAP PLMITEM #101187-0, NY Slate ELAP #10379