NYC-WTC_000273471
TEM asbestos analysis results for air samples at New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗TEM analysis results for air samples at New Stuyvesant High School, exterior/interior, received Jun 11, 2002.
NYC-WTC_000298751–000298753OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Attn: Mr. Bernard Orlan Received: 6/11/02 7:00:00 PM N.Y.C. Board of Education ATC Group #: 8051 28-11 Queens Plaza North Analysis Date: 6/11/02 Long Island City, NY 11101 Fax: (212)475-4122 Phone: (212) 477-8941 Project: New Stuyvesant H. S., 345 Chambers St., NY , NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Area Non Asbestos # Structures Sensitivity Concentration Sample l^olume Analyzed Asb Type(s) 0.5fi-5 Sfi (S/cc) (S/mm^) (S/cc) P/otes
17 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 805: -17
18 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 S051 -/s
19 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 S05I -19
20 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 8051 -20
21 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 8051 -21
MARX PEYSAKHOV MICHAEL A. GORYCKI, Ph.D.
Analyzed by Approved by:
Disclaimer: The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel, This late-Yonty responsible for data reported in stnictures/mmT This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S. Govemmenl This reports relates only to the samples reported above. Quality control data (including 95% confidence limits and laboratory and analysis' accuracy and precision) is available upon request
Accredited for NVLAP PLMTEM #101187-0, NY State ELAP #10879
Page 3 uf 3
CITY_21MC100_003091631
NYC-WTC_000298753
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000273471
TEM asbestos analysis results for air samples at New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300024
Asbestos fiber TEM analysis data for exterior/interior areas of the building, Apr 2002.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299944
TEM asbestos analysis results for abatement sites, 04/10/02.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000185047
Formal laboratory report detailing transmission electron microscopy results for asbestos fiber analysis conducted on behalf of the New York City Board of Education.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300246
TEM asbestos analysis results; AHERA method used for Stuyvesant HS samples.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298708
Asbestos fiber TEM results for air samples at the school, AHERA methodology.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300328
TEM asbestos analysis report for exterior/interior of New Stuyvesant High School, May 27, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298868
TEM asbestos analysis data for group 8210 at DOE site.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300220
TEM asbestos analysis report for New Stuyvesant High School exterior/interior areas.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299938
TEM asbestos analysis results for site, 04/09/02.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273394
Asbestos TEM analysis report for New Stuyvesant High School samples.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299213
TEM asbestos analysis results for exterior/interior areas of New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000273394
Asbestos TEM analysis report for New Stuyvesant High School samples.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000349462
Asbestos TEM results with concentrations for AHERA project at NYC school.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000194188
Formal laboratory report from ATC Associates detailing TEM asbestos fiber analysis results for a high school project in May 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299944
TEM asbestos analysis results for abatement sites, 04/10/02.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398443
Asbestos TEM analysis report for New Stuyvesant High School, Mar 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000298487
Asbestos fiber TEM analysis report for New Stuyvesant High School, May 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM asbestos analysis results for air samples at New Stuyvesant High School.
Similar indexed content
Asbestos fiber TEM analysis data for exterior/interior areas of the building, Apr 2002.
Similar indexed content
TEM asbestos analysis results for abatement sites, 04/10/02.
Similar indexed content
NYC-WTC_000185047
Formal laboratory report detailing transmission electron microscopy results for asbestos fiber analysis conducted on behalf of the New York City Board of Education.
Similar indexed content
TEM asbestos analysis results; AHERA method used for Stuyvesant HS samples.
Similar indexed content