NYC 9/11 Public Portal Document
Attn: Mr, Bernard Orlan Received: 5/29/02 9:00:00 PM
N.Y.C. Board of Education ATCGroup#: 7902
28-11 Queens Plaza North Analysis Date: 5/30/02
Long Island City, NY 11101
Fax: (212)475-4122 . Phone: (212)477-8941 ,
Project: New Stuyvesant H. S., 345 Chambers St., NY , NY ’
Exterior and Inferior of Building and Roof
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
Area Non Asbestos # Structures Sensitivity Concentration
Sample Volume Analyzed Asb Type(s) O.Sp-5 Ip (S/cc) (S/mm^) (S/cc) Notes
17 1920.00 0.0450 0 None Detected 0 - 0 00045 <22.24 <0.0045
7902 -/7
18 1920,00 0.0450 0 None Detected 10 ' ’‘ '0- : 0.0045 <22.24 <0.0045
7902 -/8
19 1920,00 0.0450 0 None Detected0 o' ■ 0.0045 <22.24 <0.0045
7902 -19
20 1920.00 0.0450 0 None Delected 0 0 0.0045 < 22.24 <0.0045
7902 -20
21 1928,00 0.0450 0 None Detected 0 0. 0.0044. <22.24 <0.0044
7902 -21
ROMAN PEYSAKHOV MICHAEL A. GORYCKI, Ph.D.
Analyzed by: iproved by;
Disclaimer The laboratory is not responsible for data reported in structures/cc, which is dependent on volume by non-laboratory personnel. ThfeTab is only responsible
for data reported in structures/mm^ This report may not be repnoduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim
product endorsement by NVLAP or any other agency of the U.S. Government. This reports, relates only to the samples reported above. Quality control data (including 95%
confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
Accredited for NVLAP PLMHEM #1011874), NY State ELAP #10879
Page 3 of 3
CITY_21MC100_003090801
NYC-WTC_000298610
OCR can misread numbers and units. Confirm readings against the page image before using them.