NYC-WTC_000297790
ATC IAQ report for Feb 13, 2002 at the referenced school.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗ATC report of IAQ measurements collected Feb 15, 2002 at the referenced school.
NYC-WTC_000297826–000297829OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr Bernard P Orlan February 18, 2002 Indoor Air Quality Assessment Page 3 H S for Leadership & Pub Service (M894') ATC Project No 15-19125-0290
Real-Time Environmental Measurements
ATC collected one hundred and forty (140) sets of real-time environmental measurements consisting of one hundred and thirty-four (134) in the school building and six (6) outdoors All fourteen floors of the school were surveyed Field data sheets are found in the Attachment Readings began at 8 35 A M and concluded after 3 40 P M The results are described below
Temperature
Indoor dry bulb temperature measurements ranged from 64 8°F to 78 1°F Six (6) of the measurements were below and fifteen (15) were above the range of 68 to 75°F (at 50 percent relative humidity) recommended by ASHRAF Standard 55-1992 during the heating season (wintertime conditions) The outdoor temperature range was 47 4°F to 53 3°F
Relative Humidity
The relative humidity indoors ranged from 22 6 percent to 39 3 percent One hundred and thirty- two (132) measurements were below the ASHRAF-recommended range of 30 to 60 percent for occupant comfort The outdoor relative humidity range was 25 2 to 31 2 percent
Carbon DioxideConcentrati^
Carbon dioxide concentrations indoors ranged from 487 ppm to 1028 ppm All of the measurements were within the ASHRAF Standard 62-1999 recommended maximum concentration of <700 ppm above the background level The outdoor (background) CO2 concentrations ranged from 459 ppm to 506 ppm Therefore, the maximum acceptable level of CO2 at this location was 1206 ppm (background level -I- 700 ppm) The highest reading was recorded m Room B06 at around 3 40 P M Levels above the recommended maximum do not indicate a health risk Carbon dioxide measurements are used as an indicator of available outdoor air The primary source of COg indoors is occupant respiration
Carbon Monoxide Concentration
Carbon monoxide concentrations indoors were 0-2 ppm These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm The outdoor CO concentrations were 2-3 ppm
Respirable Particulates (PM2 j)
Respirable particulate concentrations* indoors ranged between 1 pg/m^ to 28 pg/m^ with an average 7 pg/m^ None of the measurements were above the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2 5 micrometers or less m aerodynamic diameter The outdoor respirable particulate concentrations ranged from 39 pg/m^ to 84 pg/m^ with an average of 57 pg/m^
* The measurements made dunng this assessment were instantaneous readings, the NPAAQS is a 24-hour average
CITY_21MC100_006797751
NYC-WTC_000297828
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000297790
ATC IAQ report for Feb 13, 2002 at the referenced school.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000297874
ATC report of IAQ measurements collected on Feb 28, 2002 at the referenced school.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000297808
ATC indoor air measurements report for February 14, 2002 at the school.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000297663
Indoor air quality measurements report dated Feb 5, 2002 for the referenced school.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000297757
ATC quality report for IAQ measurements at a NYC high school in Feb 2002.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000189753
Cover letter and report summary for indoor air quality measurements collected at a school on February 27, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000256872
ATC report on indoor air quality measurements at a NYC high school site, conducted Feb 7, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000257027
Indoor air quality measurements at HS of Economics and Finance, Feb 2002.
11 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000297686
Report of IAQ measurements collected Feb 8, 2002 at the referenced New York City school.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000297722
Indoor air quality report for Feb 12, 2002 at the school, with monitoring details.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000295749
ATC memo describing IAQ measurements at the referenced NYC school.
11 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000297681
Indoor air quality report for the school, Feb 6, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
ATC IAQ report for Feb 13, 2002 at the referenced school.
Similar indexed content
ATC report of IAQ measurements collected on Feb 28, 2002 at the referenced school.
Similar indexed content
ATC indoor air measurements report for February 14, 2002 at the school.
Similar indexed content
Indoor air quality measurements report dated Feb 5, 2002 for the referenced school.
Similar indexed content
ATC quality report for IAQ measurements at a NYC high school in Feb 2002.
Similar indexed content