NYC-WTC_000295749
ATC memo describing IAQ measurements at the referenced NYC school.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗ATC memo about IAQ measurements at a NYC school for BOE.
NYC-WTC_000295745–000295748OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr Bernard P Orlan March 5 2002 Indoor Air Quality Assessment Page 3 H S for Leadershin & Public Service (M894) ATCProiectNo 15 19125 0290
Real Time Environmental Measurements
ATC collected one hundred and forty (140) sets of real time environmental measurements consisting of one hundred and twenty eight (128) in the school building and twelve (12) outdoors All fourteen floors of the school were surveyed Field data sheets are found in the Attachment Readings began at 8 18 AM and concluded after 3 51PM The results are described below
Temperature
Indoor dry bulb temperature measurements ranged from 62 1 °F to 73 3 9°F Seven (7) were below the range of 68 to 75°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55 1992 during the heating season (wintertime conditions) The outdoor temperature range was 40 4 °F to 53 8 °F
Relative Humidity
The relative humidity indoors ranged from 19 4 percent to 42 3 percent One hundred and twenty five (125) measurements were below the ASHRAE recommended range of 30 to 60 percent for occupant comfort Three (3) mdoor measurements were within the ASHRAE recommended range The outdoor relative humidity range was 19 4 to 24 1 percent
Carbon Dioxide Concentration
Carbon dioxide concentrations indoors ranged from 364 ppm to 1156 ppm All of the measurements were below the ASHRAE Standard 62 1999 recommended maximum concentration of <700 ppm above the background level The outdoor (background) CO2 concentrations ranged from 308 ppm to 581 ppm Therefore the maximum acceptable level of CO2 at this location was 1281 ppm (background level + 700 ppm) Levels above the recommended maximum do not indicate a health risk Carbon dioxide measurements are used as an indicator of available outdoor air The primary source of CO2 indoors is occupant respiration
Carbon Monoxide Concentration
Carbon monoxide concentrations indoors were 1 2 ppm These concentrations were below the NPAAQS/ASHRAE guidelme of 9 ppm The outdoor CO concentrations were 1 3 ppm
Respirable Particulates (PM2
Respirable particulate concentrations* indoors ranged between 2 pg/m^ to 26 pg/m^ with an average 7 pg/m^ None of the indoor measurements were above the NPAAQS of 65 pg/m^ 24 hour average concentration of particulate matter 2 5 micrometers or less in aerodynamic diameter The outdoor respirable particulate concentrations ranged from 30 pg/m^ to 85 pg/m^ with an average of 55 pg/m^
* The measurements made during this assessment were instantaneous readings the NPAAQS is a 24 hour average
CITY_21MC100_003085316
NYC-WTC_000295747
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000295749
ATC memo describing IAQ measurements at the referenced NYC school.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000295726
ATC Associates memo documenting indoor air quality measurements at a NYC school.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000295768
ATC report of IAQ measurements at a NYC school for BOE.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000297874
ATC report of IAQ measurements collected on Feb 28, 2002 at the referenced school.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000295866
ATC report on indoor air quality measurements at NYC school; March 14, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000189753
Cover letter and report summary for indoor air quality measurements collected at a school on February 27, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000295915
March 22, 2002 IAQ measurements at School for Leadership & [name], NYC BOE.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000295919
March 25, 2002 IAQ measurements at School for Leadership & [name], NYC BOE.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000297826
ATC report of IAQ measurements collected Feb 15, 2002 at the referenced school.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000295792
ATC report on IAQ measurements conducted at the referenced NYC school.
12 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000297790
ATC IAQ report for Feb 13, 2002 at the referenced school.
12 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000297808
ATC indoor air measurements report for February 14, 2002 at the school.
11 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000295749
ATC memo describing IAQ measurements at the referenced NYC school.
Similar indexed content
NYC-WTC_000295726
ATC Associates memo documenting indoor air quality measurements at a NYC school.
Similar indexed content
NYC-WTC_000295768
ATC report of IAQ measurements at a NYC school for BOE.
Similar indexed content
ATC report of IAQ measurements collected on Feb 28, 2002 at the referenced school.
Similar indexed content
NYC-WTC_000295866
ATC report on indoor air quality measurements at NYC school; March 14, 2002.
Similar indexed content