NYC-WTC_000294149
TEM asbestos analysis results for Stuyvesant High School samples, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗TEM asbestos analysis at Stuyvesant High School, Oct 2001.
NYC-WTC_000294071OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date; 10/05/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected.Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Zdentificaticn Analysis Parameters
Project/Site: Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5609 - 6QQ57 Floors 1-10 Date Received: 10/05/01 Grid Openings Analyzed;__ 4
Project Sample No.: SHS-1»1Q-1O/S-SO Average Grid Opening: 106.00 um
A.ir Volume ; 1967 liters Total Area Analyzed ;0^04^0 mTn2
Filter Type: MCE 25 mm diam. Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mm2 Effective Area: 3 8 5 min2 0.0044 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0. C 0.0000 0
Ambiguous 0 0 0 0 c 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 O.G 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0. 0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (Ail Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type; None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003082801
NYC-WTC_000294071
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000294149
TEM asbestos analysis results for Stuyvesant High School samples, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294048
TEM analysis parameters; 5609 sample and air volume details.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270125
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270133
TEM analysis of asbestos fibers at Stuyvesant High School; includes SAED/EDS identification.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270103
TEM analysis with SAED/EDS for Stuyvesant HS, Oct 1987.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182511
Technical data sheet recording air volume and microscopic analysis parameters for sample 5609 from Stuyvesant High School.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270090
Asbestos fiber TEM analysis on Stuyvesant High School samples for AHERA/SAED/EDS, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270087
TEM asbestos analysis results for Stuyvesant High School; diffraction and spectroscopy data.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188720
Laboratory report of asbestos fiber analysis by TEM for samples collected from floors 1-10 at Stuyvesant High School.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270106
TEM analysis with SAED/EDS, Stuyvesant H.S., Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270112
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270088
TEM asbestos analysis details for Stuyvesant High School; SAED and EDS results.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000294149
TEM asbestos analysis results for Stuyvesant High School samples, Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294048
TEM analysis parameters; 5609 sample and air volume details.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270125
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270133
TEM analysis of asbestos fibers at Stuyvesant High School; includes SAED/EDS identification.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270103
TEM analysis with SAED/EDS for Stuyvesant HS, Oct 1987.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182511
Technical data sheet recording air volume and microscopic analysis parameters for sample 5609 from Stuyvesant High School.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000294149
TEM asbestos analysis results for Stuyvesant High School samples, Oct 2001.
Similar indexed content
NYC-WTC_000294048
TEM analysis parameters; 5609 sample and air volume details.
Similar indexed content
NYC-WTC_000270125
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
Similar indexed content
NYC-WTC_000270133
TEM analysis of asbestos fibers at Stuyvesant High School; includes SAED/EDS identification.
Similar indexed content
NYC-WTC_000270103
TEM analysis with SAED/EDS for Stuyvesant HS, Oct 1987.
Similar indexed content