TEM analysis, Lab Group 10/21-01, Oct 2001

Machine-extracted title · confidence 39%

TEM analysis: sample 2, 6IS34, 385 mm2; 80 kV; EDS results.

NYC-WTC_000293792
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC ASSOCIATES INC. TEM ANALYSIS LAB GROUP #: 10/21-01

2 Sample Mo. 6IS34 Filter Type MCE 25 mr Operator

rent Spi. No. Plicer Area ,3SB mm

Instrurnenc I.D. EM LO CRX Grid I.D. <02 Disk No. Screen Magnification 16,400X (GO) Area Cl ■ 0112 4 mm Comments.

Acc. Voltage 8 C kV No. GO co de Analyzed _4 147 Strucc. Corspd .0 "O s/mm"! . 1

Length I.D. of Structure EDS GO. Structure structure Type (Nonasb. No. >0.5 um No Coord. F B C M < 5 tim Sum Chrys. Amphibole Nonasb. Ambig./ND Elements)

-3 A

Store all unrepeated spectra--^ Photo No. (from 1 in 5 aebestog- Check diffraction for asbestos Identify all atructurea uaing EDS> containing samples) Grid acceptance: I structures up to TOs/ffim (I a t 4) <50% undiBsolvea filter, overlapped or folded Struct. =: > 0.5um k > 5:1 Aspect Ratio <10% particulate coverage >50% coverage Totals N= Not Observed (EDS epectrurn or diffraction pattern) at least 20 unfolded or overlapped grid squares Positive diffraction pattern properties conforming <5% holes or opaque areas F B C M > Sum to laboratory identification criteria observed. Unuaed portion For chrysotile: 0.73nm spacing for (020) reflectiona, 0.53nm apaeinf (or the layer line repeat, streaking of niter Chrysotile Avoided portion of (110) and (130) renecUons. of niter Por amphiboles: O.SSnm layer line repeat, and approx. (2mm wide) 3.5 ratio of non-twlnned layer line spot spacing to Amphibole layer line repeat distance (O.S3nm). \N= EDS Spectrum conforming to laboratory IdenUrication criteria observed. AMPHIBOLES Ambiguous F= Single Fiber (1-3 intersectiona s 1-3 fibers) Amosite Bundle (>3 fibers <1 fiber diameter apart) SSmm filter Crocidolite Non —asbestos C= Cluster (>3 intersections) I----------- |' Stoppln, Rul» !'----------- , . Anthophyllite ySD= No structure. Detected j >a° ./c.°. »r In 1.1 « G.o. j Tremolite Non-Identified Actinolite L:\OATA\PRIVtTE\MIKEC\ CADOVEKD 9/22/98

CITY_21MC100_003082485

NYC-WTC_000293792

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000293792Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

TEM analysis, 62416, 10/28/01

NYC-WTC_000292768

TEM analysis for Lab Sample 62416; MCE 25 mm, EDS data; New Stuyvesant High School project.

Similar indexed content

Compare copies and versions →