NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, New Stuyvesant H.S., Oct 2001

Machine-extracted title · confidence 42%

TEM asbestos fiber analysis with diffraction/EDS for New Stuyvesant High School samples.

NYC-WTC_000293679
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

K.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/20/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive Z-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identificat-ion Analysis Parameters

Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5730 61695 Various Sites Inside and Outside the Building Date Received: 10/19/^ Grid Openings Analyzed:__ 4

Project Sample No.: 05 Average Grid Opening: 106.00 um

Air Volume :2p C0 JJ,te^ Total Area .Analyzed: 0.0450 mm2

Filter Type-. MCE 25 mm diam. Pore Size: 0.45 um Analytical Sensitivity:22^2 s2mm2 Effective Area: 385 mm2 0.0043 s/cc

FIBROUS PARTICULATES AJJALY2ED Humber Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc ncfm/m3

Chrysotile Asbestos 0 0 c 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 C 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 c 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0. 0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Tlnalysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003082359

NYC-WTC_000293679

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000293679Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293729

Asbestos fiber analysis by TEM at New Stuyvesant High School, project site listed, October 2001.

Similar indexed content

NYC-WTC_000293899

TEM SAED/EDS results; exterior/interior building sampling details.

Similar indexed content

NYC-WTC_000292750

TEM analysis parameters for exterior/interior of building at New Stuyvesant H.S., 10/28/01.

Similar indexed content

NYC-WTC_000293733

TEM analysis for asbestos identification at New Stuyvesant High School, Oct 2001.

Similar indexed content

NYC-WTC_000293769

TEM analysis with SAED/EDS; exterior & interior building samples.

Similar indexed content

Compare copies and versions →