NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, New Stuyvesant HS, Oct 2001

Machine-extracted title · confidence 42%

TEM analysis with SAED/EDS for New Stuyvesant High School, Oct 2001.

NYC-WTC_000293640
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/18/01

ASBESTOS FIBER ANALYSIS BY TRTkNSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAEDi and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Ident/ification Analysis Parameters

Project/Site; New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5725 61639 Exterior & Interior of Building & Roof Date Received; 10/18/01 Grid Openings Analyzed:__ 4

Project Sample No.: 07 Average Grid Opening: 106.00 vxm

Air Volume •. 1920 1it€rs Total Area Analyzed ;.0;£450 jnm2

Filter Type; MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity Effective Area : 385 mrri2 0.Q045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5U!T, Struct/mm2 Struct/cc ngm/m.3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0 . 0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 c 0 c 0 0 0.0 0.0000 N/A Ho Identification 0 0 0 0 0 0 0.0 0 . OOOC N/A

Totals [All Structures) 0 0 0,0 0.OOOC N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003082314

NYC-WTC_000293640

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000293640Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000294016

TEM analysis of exterior/interior air at New Stuyvesant H.S., Oct 2001.

Similar indexed content

NYC-WTC_000293643

Asbestos TEM analysis at New Stuyvesant High School, TEM sample 5725; SAED/EDS identification.

Similar indexed content

NYC-WTC_000270665

TEM analysis by SAED/EDS for New Stuyvesant HS, exterior/interior, 10/2001.

Similar indexed content

Compare copies and versions →