NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, New Stuyvesant H.S., Oct 2001

Machine-extracted title · confidence 29%

TEM-based asbestos analysis for NSHS site, Oct 2001.

NYC-WTC_000293528
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITEE NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/14/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; AHERA Final Rule, ERA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample. Identification Analysis Parameters

Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEN Sample No.: 5687 61065 Exterior & interior of Building & Roof Date Received: 10/14/01 Grid Openings Analyzed-.__4

Project Sample No.: NSHS-EIR-10/13-12 Average Grid Opening: 106.00 um

Air Volume : 1926 ]J;ters Total Area Analyzed:0;T450 rnni2

Filter Type; MCE 25 mm diam,, Pore Size: 0.45 um Analytical Sensitivity: 22;.^2 s/mrr^ Effective Area: 3 85 inm2 0.0044 s/cc

FIBROUS PARTICULATES 7\NALYZED Number Observed concentration Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc ngm/m3

Cnrysotile Asbestos D 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0

Non-Asbestos 0 0 0 0 0 0 0.0 C.OOOO N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 C . 0000 N/A The estimated uncertainty of this analysis is 1 standard deviation

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003082178

NYC-WTC_000293528

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000293528Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293425

Asbestos TEM analysis, exterior/interior, 10/09/01.

Similar indexed content

NYC-WTC_000270302

TEM analysis of sample 5649 from New Stuyvesant High School, Oct 2001.

Similar indexed content

NYC-WTC_000270381

TEM asbestos analysis report for exterior/interior of building, Oct 2001.

Similar indexed content

Compare copies and versions →