TEM asbestos analysis data sheet, 2nd floor host

Machine-extracted title · confidence 33%

TEM asbestos air analysis counts with laboratory details and magnification for 6/1/02.

NYC-WTC_000292719–000292736
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TEM Asbestos (air) Count Sheet Client Name: NYC BOE Volume filters'): 1816 Lab Group #: 7932 Filter Type / Filter Area: MCE 385 mm^ Lab Sample#: 4 Grid Opening Size: 0.01124 Client Sample #: 07 Area Examined: 0.04496 mm^ gRlQBOX; Magnification: 20,000 GRIDW: Accelerating Voltage: 100 KeV # Grid Openings: 4 Analysis Date: 6/1/02

Analysis Performed By: ROMAN PEYSAKHOV

GO. Structure Stuictura Type Length ID of Structure N or V EDS No (Nonadb F B C M >*05 p >=5|j Chrys Amphibole Nonasb Ambig/ND Elements) No ' Coord <5p

TST I

h I

Struct - > 0.5u > 5:1 Aspect Ratio Grid acceptance: Positive diltisction pattern propertlas conferming to <60% undissolved Bter, overlapped or folded Tot^ V i-asiiiveoini^p«BiniriopBrow wnion™iiBB ^ig^partteulate coverage >50% coverage ate laboratofy klentilicationcriteris observed least 20 unfolded or overfapped grid squares <5% F B C M >5p ; Y=EDSspeclram contonrtng to laboratory holes or opaque areas idenafcatjoncnteriaobsaved Chrysotile AMPHIBOLES Amphibole F = Single Fiber Amosite B * Bundle {<3 fibers <1 fiber diameter apart Crocidolite Ambiguous C = Cluster (>3 Intersections) Anthophyllite Non-Asbestos Tremolite M’Matrix Actinolite Non-Identificd NSC ’ No Structures Detected

CITY_21MC100_003080736

NYC-WTC_000292722

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000292722Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →