TEM asbestos air analysis data, 7740 project, May 2002

Machine-extracted title · confidence 25%

TEM asbestos air analysis data for NYC BOE site 7740; May 14, 2002.

NYC-WTC_000292316–000292333
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TEM Asbestos (air) Count Sheet Client Name; NYC BOE Volume niters); 1816 Lab Group #: 7740 Filter Type / Filter Area; MCE 385 mm^ Lab Sample #; 2 Grid Opening Size: 0.01124 •Client Sample #; 05 Area Examined; 0.04496 mm’ GRID BOX; Magnification: 20,000 GRID IP: Accelerating Voltage; 100 KeV # Grid Openings; 4 Analysis Date; 5/14/02

Analysis Performed By: MARKPEYSAKHOV

GO. Structure Sfructure Type Length ID of Structure N or V EDS No ^^5)j ;>=5p Nonasb (Nonadb F B C M Chfys AmpMbote Ainbig/ND Elements) No Coord <5m

---- -

Struct« > 0.5)1 > 5:1 Aspect Ratio Grid acceptance: Positive dHIrsetion pattern propertiea conforming to <S0% undlsaotesd Mar, ovarteppad »folded Totak latnrebMy idenSfleation criteria observed <10% parUculala coMrage >50% coverage ale least 20 unfolded or overlapped grid squares <5% F B C M • EOS spectrum conforming to laboratory holes or opaque areas identification criteria observed Chrysotile AMPHIBOLES ~ Amphibole F = Smgte Fiber Amosite B = Bundle (<3 fibers <1 fiber diameter apart CroctdolitB I Ambiguous C = Cluster (>3 Inletseclions) Anthophyllite , Non-Asbestos Tremolite M = Matrix Non-ldentified Actinolite NSO = No Structures Detected

CITY_21MC100_003080283

NYC-WTC_000292317

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000292317Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →